Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

410 Differential Refractive Index Detector, Waters (CAT#: STEM-CPO-0727-ZJF)

Highlights

A long-life LED light source with special circuitry to compensate for changes in intensity over time
A microprocessor-controlled keyboard with digital readout
Auto zero, temperature limit alarm and cell purge functions

Cat Number: STEM-CPO-0727-ZJF

Application: For chromatography

Model: 410

Add to Cart



Description

The manufacturer of the 410 Differential Refractive Index Detector, Waters is Waters.
Refurbished Waters 410 RI detector complete with flow cell. The Waters 410 is designed for HPLC and GPC applications. This detector is particularly suited for determining the molecular weight distribution of polymers or carbohydrates in food products. The temperature-controlled optics and the patented countercurrent heat exchanger increase baseline stability for reproducible results. The 410 can be operated on its own or programmed from a waters controller.

Specification

Condition: Refurbished, Certified Pre-owned
Rl Range: 1.00 to 1.75 RIU
Measurement Range:
5×10-3 RIU maximum FS (SENS= 1, SF=1)
5 x 10-a RIU minimum FS (SENS=1024, SF=100)
Flow Rate: 0.3 -10 mL/min
Noise: 2.0 x 10-8 RIU, (TC = 1, SF = 20, SENS = 32,
THF at 24 °C with restrictor coil)
Drift: 2.5 x 10-7 RlU/hr (static with THF)
Sensitivity Settings: 1, 2, 4,8, 16, 32, 64, 128, 256, 512, 1024
Time Constant Filter Settings: 0.2, 1, 3, 10 seconds
Recorder Output: 0 to 10 mV
Temperature Control:
Internal oven 30 to 50 °C
External column heaters Ambient to 150 °C
Light Source: 930 nm pulsed Light Emitting Diode (LED)
Flow Cell: Fused quartz
Cell Volume: 10 uL
Pressure Limit: 100 psi
Fluid Path Materials: 316 stainless steel, Dynasii®, Suprasil II®, Teflon®, Kalrez®, quartz
Optional: Waters column heater WAT038040 (m/n CHM)

Features

A long-life LED light source with special circuitry to compensate for changes in intensity over time
A microprocessor-controlled keyboard with digital readout
Auto zero, temperature limit alarm and cell purge functions
An internal heater with counter heat exchangers to protect the solvent stream from changes in ambient temperature
Memory protection in the event of a power failure
A compressed output function which keeps large peaks on scale without losing smaller peaks
Built-in over-pressure protection for the cell
Built-in diagnostics that check the operation of the instrument
Four time constant settings from 0.2 to 10.0 seconds