5975C Series GC/MSD System (CAT#: AM-LE-0269-Y)

Highlights

• Inert ion source, now programmable to 350°C-provides enhanced response to active compounds and late eluents
• The three-axis HED-EM detector provides the highest signal-to-noise ratio specification on the market (1 pg OFN, 400:1)
• Proprietary hyperbolic quadrupole improves performance, up to 1050 u the unique stability of the quartz monomer allows the analyzer to be heated to 200°C to eliminate common pollution at lower temperatures

Cat Number: AM-LE-0269-Y

Application: The instrument's applications range from simple air and drinking water to the most complex volatile to semi-volatile analytes in food and soil/sludge matrices.

Add to Cart



Description

7000A Triple Quadrupole GC/MS Instrument is manufactured by Agilent Technologies, equipped with a three-axis HED-EM detector, improves the productivity of your laboratory and advanced analytical capabilities, helps you get better results faster, and 7890A gas phase The powerful functions of the chromatograph complement each other perfectly.

Specification

Temperature Range: up to 350C (Ion Source), up to 200C (Analyzer)
Ionization Method(s): EI, PCI, NCI
Mass Analyzer: Triple Quadrupole (Triple-Axis HED-EM)
Scanning Speed: up to 12,500 u/s
Mass Range: up to1050 u

Features

• Inert ion source, now programmable to 350°C-provides enhanced response to active compounds and late eluents
• The three-axis HED-EM detector provides the highest signal-to-noise ratio specification on the market (1 pg OFN, 400:1)
• Proprietary hyperbolic quadrupole improves performance, up to 1050 u the unique stability of the quartz monomer allows the analyzer to be heated to 200°C to eliminate common pollution at lower temperatures
• Simultaneous SIM/scanning mode allows you to selectively monitor ions of interest with a highly sensitive SIM, while acquiring searchable library scan data
• Safe operation, low cost, hydrogen carrier
• Trace ion detection and second-generation deconvolution report software (DRS) can accurately identify and quantify trace components blended with other analytes or matrix peaks
• All ionization modes (PCI, NCI, and EI) use standard Cl sources and are performed in an automatic sequence the AutoCI function makes CI as simple as EI
• High-performance and entry-level models complement the Agilent 7890A GC, 6890 GC, and 6850 GC perfectly

Related Products

325-MS LC/MS Triple Quadrupole Mass Spectrometer from Agilent Technologies
5975C Series GC/MSD System from Agilent Technologies
5975T Low Thermal Mass (LTM) Transportable GC/MSD from Agilent Technologies