ABI 785A Programmable HPLC Absorbance Detector, Applied Biosystems (CAT#: STEM-CPO-0360-ZJF)

Highlights

LC Programmable Wavelength Detector
Compact, User-Friendly Design
Front Panel or Remote Operation

Cat Number: STEM-CPO-0360-ZJF

Application: For chromatography

Model: ABI 785A

Add to Cart



Description

The manufacturer of the ABI 785A Programmable HPLC Absorbance Detector, Applied Biosystems is Applied Biosystems.
Refurbished Applied Biosystems 785A Programmable HPLC Absorbance Detector.
The ABI 785A is a LC variable wavelength detector that can operate from 190-700nm. Nitrogen purge hook-up is present for desired operation below 200nm. This instrument is fully programmable from the front-panel user interface, or it can be controlled remotely from the RS232 port.

Specification

Condition: Refurbished, Certified Pre-owned
Wavelength Range: 190 - 700 nm
Wavelength Accuracy: ± 1 nm
Wavelength Reproducibility: ± 0.5 nm
Bandwidth: 5 nm
Absorbance Range: 0.0005 to 3.000 AUFS, in 0.0001 increments from 0.0005 to 0. 1, and 0.01 increments above 0.1 AUFS
Noise (210-280 nm, 1 sec rise time, standard 12 ul flowcell): < ± 1 X 10-5 AU
Program Storage: 8 Programs / 32 Events Each
Optics: Dual Beam
Recorder Output: 10 mV Full Scale for any Selected Range
Drift: <1 x 10-4 AU/hour, after Warm-Up
Operation Below 200 nm: N2 Purge Provision
Noise Filter: Digitally controlled active with rise times selectable from 0.02 to 5.0 seconds 8 steps
Programmable Functions: Time, wavelength, range, rise time, auto zero, relay closures, program number, number of injections, shutdown procedure (program execution via run table)
Scan: Stopped flow scan, scan speed selectable from 0.2 to 1.0 nm/sec
Flowcell Backpressure: 500 psi
Self Diagnostics: Self-check routine upon demand. Complete self-check routine performed upon power-up. Continuous monitoring of power supply condition, lamp status, fan operation, and leak sensor
Control Outputs: 4 SPDT relays, 1 A/48 V (max); relays retain state even with power off
Optional: 785A board for parts p/n 1700-0344.

Features

LC Programmable Wavelength Detector
Compact, User-Friendly Design
Front Panel or Remote Operation
Low Noise, Accurate, Stable Platform
Built-in Self Diagnostics