Acquity 2996 Photo Diode Array Detector, Waters (CAT#: STEM-CPO-0364-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-CPO-0364-ZJF

Application: For chromatography

Model: Acquity 2996

Add to Cart



Description

The manufacturer of the Acquity 2996 Photo Diode Array Detector, Waters is Waters.
Refurbished Waters 2996 Acquity Photo Diode Array Detector. (2996 PDA Detector Acquity Ultra Performance LC) (p/n 186015025). Wavelength Range: 190 to 500 nm. Wavelength Accuracy: ±1 nm. The Acquity 2996 can be used for in-vitro diagnostic testing to analyze many compounds, including diagnostic indicators and therapeutically monitored compounds.
The Acquity UPLC® photodiode array (PDA) detector allows laboratories to detect and quantify lower concentrations of sample analytes and compare spectra across wavelengths and broad concentration ranges. It has data rates of up to 80 Hz, noise specifications of 10 μAU, and an extended linear range. With the PDA detector, users can fulfill multiple UltraPerformance LC®/MS detection strategy requirements for the identification of components that are difficult to resolve by conventional HPLC-based methods. Trace impurities at levels to 0.004% with low signal-to-noise ratios, high optical and digital resolution, and library matching can be quantified.

Specification

Condition: Refurbished, Certified Pre-owned
Wavelength range: 190 to 500 nm
Light source: Prealigned, Deuterium lamp
Spectral Resolution/Optical Bandpass: 1.2 nm per photodiode with a total of 512 photodiodes, digital and optical (3D-mode)
Digital Resolution: 1.2 nm – 600 nm (2D mode)
Wavelength accuracy: ±1 nm
Linearity range: 5% at 2.0 AU, propylparaben, at 256 nm
Spectral resolution: 1.2 nm
Baseline noise: ±1.5 × 10–5 AU peak-to-peak, dry, at 254 nm
Drift:
1 × 10–3 AU/hour at 254 nm (after warm-up)
∆T ≤ 1°C per hour
Operation temperature: 4 to 40 °C (39 to 104 °F), not to vary more than 1 °C per hour (to prevent drift)
Relative humidity: 20 to 80%, noncondensing
Power: Grounded ac, 100 to 240 Vac
Power requirements: 100-230 VAC
Frequency range: 50 to 60 Hz
Path Length: 10 mm (standard analytical cell)
Cell volume: 8 µl (standard analytical cell)
Pressure Limit: 1000 psi (standard analytical cell)
Wetted materials: 316 stainless steel, fused silica Tefzel

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty