Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Acquity H-Class UPLC Sample Manager-FTN, Waters (CAT#: STEM-CPO-0368-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-CPO-0368-ZJF

Application: For chromatography

Model: Acquity H-Class SM-FTN

Add to Cart



Description

The manufacturer of the Acquity H-Class UPLC Sample Manager-FTN, Waters is Waters.
Refurbished Waters Acquity H-Class UPLC sample manager-FTN (p/n 186015017).
The Waters Acquity Sample Manager with Flow-Through Needle (SM-FTN) offers excellent carryover performance. The Acquity UPLC I-Class System is available with a choice of column management options.

Specification

Condition: Refurbished, Certified Pre-owned
Total system bandspread, 5σ:
6 to 9uL
Test conditions:
Mobile phase: 90: 10 water/acetonitrile
Flow rate: 0.1 to 1.0 mL/min in 0.1 mL/min increments
Weak wash: 90: 10 water/acetonitrile
Strong wash: 90: 10 water/acetonitrile
Sample: 0.01 mg/mL caffeine (1-ul injection volume); 0.030 mg/mL caffeine (0.5-ul injection volume); 0.050 mg/mL caffeine (0.2-ul injection volume)
Column compartment: CH-A
Total system dwell volume: <100uL, default configuration
Integrated leak management: Leak sensors, as standard, and safe leak handling. Drip trays direct all leaks to the front of the instrument, and then into waste line.
Operating flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments
Maximum operating pressure:
124,106 kPa (1241 bar, 18,000 psi) up to 1mL/min
82,737 kPa (827 bar, 12,000 psi) up to 2mL/min
pH range: pH 2 to 12
Gradient mixers:
Binary solvent manager:
50 uL mixer/filter (Standard)
100 uL mixer/filter (Optional)
380 uL mixer/filter (Optional)
Unattended operation:
Leak sensors, full 96-hour diagnostic data display through Acquity UPLC console software
Injection cycle time:
<15s
Test conditions:
System: BSM, SM-FTN, Acquity TUV, CH-A
Solvent A: water/acetonitrile, 90: 10
Solvent B: 100% acetonitrile
Weak wash: water/acetonitrile, 90: 10
Strong wash: water/acetonitrile, 90: 10
Column: Acquity UPLC BEH C18 1.7 μm, 2.1 × 50 mm
Sample: caffeine at 0.04 mg/mL in water/acetonitrile, 90: 10
Mobile phase: 100% solvent A
Isocratic chromatography
Flow rate: 0.4mL/min
Injection volume: 1uL
Load ahead mode: enabled
Run time: 2.0 min
Detection: UV at 273 nm