Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1100 Binary DAD HPLC System, Injection Volume 0.1–100 μl Standard Range, HP Agilent (CAT#: STEM-CPO-0028-LGZ)

Cat Number: STEM-CPO-0028-LGZ

Application: For UHPLC analysis.

Add to Cart



Description

Agilent 1100 High Performance Liquid Chromatography (HPLC) System with Binary Pump and Diode Array Detector

Includes
Agilent 1100 Model G1312 Binary Pump and Solvent Module
Agilent 1100 Model G1313 Autosampler (ALS)
Agilent 1100 Model G1315 Diode-Array Detector (DAD)
Agilent 1100 Model G1316 Thermostatted Column Compartment (TCC)
Agilent 1100 Solvent Tray with 2 solvent bottles
Computer Data System with NEW Data (Clarity for Windows 10) Analysis Software
New 19″ Flat Panel Monitor
All cables, keyboard, mouse, & complete performance documentation
Optional / Sold Separately
Agilent 1100 Model G1322 Vacuum Degasser
Recertified HPLC systems are refurbished and tested by trained engineers and fully meets specifications.

Additional information

The binary pump has extremely high flow precision in solvent mixing, suitable for a wide range of research and routine applications, and the flow range is suitable for 0.001 ml/min to 5 ml/min.

The Thermostatic Column Compartment (TCC) is a peltier-based design that provides stable operation at ambient, sub-ambient, and super-ambient temperatures.

Diode Array Detectors (PDAs) have excellent sensitivity across the entire wavelength range, including UV and visible. It features deuterium and tungsten lamps to ensure the highest light output, 1024 diodes from 190 to 950 nm and programmable slits to optimize wavelength resolution.

The Agilent 1100 Series HPLC systems are designed to continuously improve laboratory productivity by delivering consistent results and optimal instrument performance. The Agilent 1100 Modular Series ensures efficient mixing and pulse-free solvent delivery, providing users with fast and accurate results. HPLC systems with extensive diagnostics and compatible data analysis software support on-site or remote troubleshooting, allowing most faults to be identified and repaired immediately.

The Agilent 1100 HPLC design builds on the legacy of the HP 1050 series and made it modular in 2000.

The 1100 Series system incorporates an electronically activated inlet valve, synchronized with piston stroke, capable of eliminating vapor formation in volatile solvents. It also features a high-speed proportional valve and a pre-configured vacuum degasser. The series is designed for operation with a handheld controller or computer running Clarity software, making operation smooth and efficient. With this highly functional and innovative system, the Agilent HPLC 1100 is extremely easy to use and maintenance free.

One of the key features of an in-line vacuum degasser is that it reduces operating costs and ensures top-notch performance without the use of helium. Additional features include built-in wavelength verification. A virtually pulse-free stable solvent flow is also guaranteed. 20,000+ other users can't be wrong.

HPLC system configuration

The modularity of the Agilent 1100 HPLC hardware allows for many different configurations. Combinations of various modules including pumps and detectors are possible in order to meet certain applications and requirements. GMI can accommodate and support all of these, including mass spectrometers. A typical configuration includes pumps, detectors, autosamplers, vacuum degassers, solvent modules, clarity software, computer systems, HPIB cables, and manuals.

Modules include 1100 Series IV, Equal Frequency or Binary Pumps, 1100 Series Variable Wavelength Detector (VWD), Diode Array Detector (DAD), Refractive Index (RI), or Fluorescence (FLD G1329) detectors. Both VWD and DAD use holmium oxide filters for automatic wavelength verification and tracking of detector performance characteristics. The Agilent 1100 detector also features a new design that allows front-channel exchange of flow cells and pre-aligned lamps.

Specification

Condition: certified pre-owned
Pump (G1312) Flow precision: 0.3% RSD (typically < 0.15% RSD)
Binary: 0.001–5 ml/min
Settable composition range: 0–100%, in 0.1%
DAD Detector (G1315): 190–950 nm
Short-term noise: ± 1 × 10-5 AU, at 254 nm, ± 1 × 10-5 AU, at 750 nm
Spectral analysis: Yes with optional software package
Autosampler (G1313): Up to 100 vials
Injection volume: 0.1–100 μl standard range
Optional extension:
• Up to 1800 μl
• Up to 5000 μl
Column Compartment (TCC) (G1316): 10 degrees below ambient to 80 °C
Column capacity: Three 30-cm columns
System Performance Specifications: Baseline noise: ±1 × 10-5 AU, at 254 nm, Ret. precision: < 0.3 % RSD, Inj. vol. precision:Typically < 0.5 % from 5–100 μl
GMI Trade-in Trade-up eligible: Yes, ask your rep ….there is no planned obsolescence with GMI
Optional Instrument Modules:
G1310 Isocratic Pump
G1312 Binary Pump
G1314 Variable Wavelength Detector
G1365 MWD Detector
G1321 Fluorescence Detector
G1362 Refractive Index Detector
G1367 ALS WPALS
G1329 ALS Temp Controllable
G1330 ALS Temp Controller
G1323 Control Module “Gameboy”
G1364 Fraction Collector

Related Products

GE AKTA Pilot, pH Range 0–14, GE AKTA (CAT#-STEM-CPO-0006-LGZ)
AKTA Basic (10mL) – Fast Protein Liquid Chromatograph, Automatic Self-Diagnostic Tests, GE AKTA (CAT#-STEM-CPO-0007-LGZ)
GE AKTA Avant Preparative Chromatography System, Complete Packsize 1 Piece, GE AKTA (CAT#-STEM-CPO-0008-LGZ)
GE ÄKTA FPLC™ Fast Protein Liquid Chromatograph, Pressure Range 0-5 MPa, GE AKTA (CAT#-STEM-CPO-0009-LGZ)
GE AKTA Prime Liquid Chromatography System, The Latest LC Technology, GE AKTA (CAT#-STEM-CPO-0010-LGZ)
Advertisement