Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1100 Series - G1315A HPLC Diode Array Detector, Agilent Technologies (CAT#: STEM-C-0036-LGZ)

Highlights

1. The HP Agilent 1100 G1315A Diode Array Detector allows the addition of spectral acquisition in HPLC analysis.
2. The detector can validate the separation of quality with peak Purity, multiple signal and spectral libraries, interactively or automatically run as the customer's analytical quantification.
3. The 1100 DAD has the highest sensitivity or spectral resolution, a wavelength range from 190 to 950 nm, programmable slits, and provides the holmium oxide wavelength to verify GLP compliance.

Cat Number: STEM-C-0036-LGZ

Application: For HPLC system.

Model: 1100 Series - G1315A

Add to Cart



Description

The manufacturer of Agilent 1100 Series - G1315A HPLC Diode Array Detector is Agilent Technologies. Model is 1100 Series - G1315A. The Agilent 1100 Series G1315 Diode Array Detector is designed for maximum optical performance. With flexible slit Settings, ranging from fine band to highest sensitivity, fine structure of benzene can be displayed at 1 nm setting, even at 0.7 mAUFS. Slits 8 or 16 nm wide can be selected to reduce baseline noise and thus improve sensitivity.

Specification

Condition: used
Wavelength range: 190-950 nm
Light source: Deuterium and tungsten lamps
Detection type: 1024 - element photodiode array
Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
Drift: 2° x 10-3 AU / hr at 254 nm
Linear absorbance range: > 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Wavelength bunching: 1 - 400 nm
Diode width: < 1 nm
Control and data evaluation: Agilent Chemstation for LC
Slit width: 1, 2, 4, 8, 16 nm

Features

1. The HP Agilent 1100 G1315A Diode Array Detector allows the addition of spectral acquisition in HPLC analysis.
2. The detector can validate the separation of quality with peak Purity, multiple signal and spectral libraries, interactively or automatically run as the customer's analytical quantification.
3. The 1100 DAD has the highest sensitivity or spectral resolution, a wavelength range from 190 to 950 nm, programmable slits, and provides the holmium oxide wavelength to verify GLP compliance.
4. The temperature management system ensures optimal baseline stability even in rough environmental conditions.
5. The agilent 1100 series diode array detector's two lamps ensure maximum light output with minimum detection across the entire wavelength range.
6. The use of 1024 diodes and a programmable optical slit from 1 to 16 nm ensures the best possible spectral bandwidth.

Related Products

Waters 2487 HPLC UV/VIS Detector, Waters Corporation(CAT#-STEM-C-0099-LGZ)
Alltech 3300 ELSD ELSD Controller, Grace(CAT#-STEM-C-0103-LGZ)
Waters 480 HPLC UV Detector, Waters Corporation(CAT#-STEM-C-0106-LGZ)
Waters Acquity QDa Mass Detector, Waters Corporation(CAT#-STEM-C-0133-LGZ)
Waters Acquity TUV Detector UPLC TUV Detector, Waters Corporation(CAT#-STEM-C-0136-LGZ)
Pharmacia Optical Unit UV-1 FPLC UV Detector, Pharmacia Fine Chemicals(CAT#-STEM-C-0249-LGZ)