Agilent 1100 Series - G1364C HPLC Fraction Collector, Agilent Technologies (CAT#: STEM-C-0048-LGZ)

Highlights

1. Depending on sample volume, flow rate, and type of collection container, the user can choose from three dedicated distillate collectors.
2. G1364C design flow rate less than 10 mL/min (can be modified to a higher flow rate).
3. The G1364C can be used in vials, tubes up to 75mm high, orificles and 40 funnel trays connected to any size external position.

Cat Number: STEM-C-0048-LGZ

Application: For analytical scale applications.

Model: 1100 Series - G1364C

Add to Cart



Description

The manufacturer of Agilent 1100 Series - G1364C HPLC Fraction Collector is Agilent Technologies. Model is 1100 Series - G1364C. The design of Agilent 1100 HPLC G1364C Fraction Collector optimized the fraction collection capability.

Specification

Condition: used
Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
Maximum tube volume: ca. 45 mL
Maximum flow rate: 100 mL / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
Delay volumes [μL]:
Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
Diverter valve: ~15
Diverter valve to needle: ~110
Needle: -~5
Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
Diverter Valve: 3/2 Diverter valve with low internal volume (15 μL), switching time < 100 ms, maximum operating pressure 6 bar
Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Features

1. Depending on sample volume, flow rate, and type of collection container, the user can choose from three dedicated distillate collectors.
2. G1364C design flow rate less than 10 mL/min (can be modified to a higher flow rate).
3. The G1364C can be used in vials, tubes up to 75mm high, orificles and 40 funnel trays connected to any size external position.

Related Products

Agilent 1100 Series - G1364D HPLC Fraction Collector, Agilent Technologies(CAT#-STEM-C-0049-LGZ)
Gilson FC204 HPLC Fraction Collector, Gilson(CAT#-STEM-C-0197-LGZ)
Transgenomic FCW 200 Wave HPLC Fraction Collector, Transgenomic (CAT#-STEM-C-0202-LGZ)
Amersham Biosciences GE FRAC-900 FPLC Fraction Collector, Amersham Biosciences(CAT#-STEM-C-0204-LGZ)
Amersham Pharmacia Biotech Frac-950 FPLC Fraction Collector, Amersham Biosciences Corp.(CAT#-STEM-C-0205-LGZ)
Shimadzu FRC-10A HPLC Fraction Collector, Shimadzu Excellence in Science(CAT#-STEM-C-0206-LGZ)
Advertisement