Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler, Agilent Technologies (CAT#: STEM-C-0054-LGZ)

Highlights

1. A micro Rheodyne® valve and needle seat, ring and seat capillaries are optimized to minimize dispersion.
2. High resolution measurement equipment provides high resolution, ten times better than standard automatic samplers.
3. Enables bypass operation and low delay volume.

Cat Number: STEM-C-0054-LGZ

Application: For HPLC system.

Model: 1100 Series - G1377A

Add to Cart



Description

The manufacturer of Agilent 1100 Series - G1377A HPLC Well Plate Autosampler is Agilent Technologies. Model is 1100 Series - G1377A. Designed for capillary LC, sample injection range: nL to μL.

Specification

Condition: used
GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range:
– 8 µL in 0.01 µL increments with the small loop capillary
– 40 µL in 0.01 µL increments with the extended loop capillary
Precision:
Typically < 0.5 % RSD of peak areas from 5 – 40 µL,
Typically < 1 % RSD from 1 – 5 µL
Typically < 3 % RSD from 0.2 – 1 µL
Sample viscosity range: 2 – 5 cp
Sample capacity:
2× well-plates (MTP) + 10 × 2 mL vials
100 x 2 mL in one tray
40 x 2 mL in half tray
Injection cycle time:
Typically, < 30 s using following standard conditions:
Default draw speed: 4 µL/min
Default eject speed: 10 µL/min
Injection volume: 0.1 µL
Carry-over:
Typically < 0.05 % using the following conditions:
Column: 150 x 0.5 mm Hypersil ODS, 3 µm
Mobile phase: Water/Acetonitrile = 85/15
Column Flow rate: 13 µL/min
Injection volume: 1 µL caffeine (=25ng caffeine), 1 µL water to test carryover
Outside wash of needle before injection: 20 sec with water using flush port

Features

1. A micro Rheodyne® valve and needle seat, ring and seat capillaries are optimized to minimize dispersion.
2. High resolution measurement equipment provides high resolution, ten times better than standard automatic samplers.
3. Enables bypass operation and low delay volume.

Related Products

Thermo Scientific Accela Autosampler HPLC Autosampler, Thermo Fisher Scientific(CAT#-STEM-C-0129-LGZ)
Rainin AI-200 Autosampler, Rainin(CAT#-STEM-C-0144-LGZ)
Leap Technologies CTC Analytics HPLC Well Plate Autosampler, Leap Technologies(CAT#-STEM-C-0187-LGZ)
Thermo PAL HTC-Accela1-TMO HPLC Well Plate Autosampler, Thermo Fisher Scientific(CAT#-STEM-C-0252-LGZ)
Waters ACQUITY Sample Organizer UPLC Autosampler Loader, Waters Corporation(CAT#-STEM-C-0269-LGZ)

Other recommended products

Advertisement