Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1200 Quat MWD System, HP Agilent (CAT#: STEM-CPO-0033-LGZ)

Highlights

Compact, benchtop design built on the "nearly perfect" 1100
Wide flow range up to 10 ml/min (at 200 bar) enables semi-preparative separation
Wide selection of autosamplers, full flexibility in injection volumes and sample containers

Cat Number: STEM-CPO-0033-LGZ

Application: It is a workhorse for the demanding needs of any QA/QC lab for the most advanced analytical and method development applications.

Model: G1314

Add to Cart



Description

Include

Agilent Model G1311 quaternary pump
Agilent Model G1365D multiple wavelength detector
Agilent Model G1322 degasser
Agilent Model G1329 autosampler
Agilent Model G1316 thermostatted column compartment
Agilent 1200 Solvent Tray with 2 solvent bottles
Computer Data System with NEW Data (Clarity for Windows 10) Analysis Software
New 19″ Flat Panel Monitor
All cables, keyboard, mouse, & complete performance documentation
Like the 1100 series the 1200 model is a workhorse for the demanding needs of any QA/QC lab for the most advanced analytical and method development applications.

At the heart of any HPLC system is the pump. The 1200 4th pump model G1311 is designed for routine method development and high-throughput gradient applications with maximum flexibility by accessing multi-solvent gradients of up to 4 solvents. Precise flow plus low pulsation = awesome.

The G1314 VWD detector provides high sensitivity information from 190 to 600 nm. The dual lamp design and temperature control of the Agilent 1200 Series VWD ensure outstanding sensitivity....it won't limit your analytical capabilities.

The repeatability and lack of carryover typical of the 1200 Series autosamplers is astronomically outstanding. Superior injection precision and minimal carryover make your runs dependable day in and day out. The 1200 Autosampler provided precision levels of <0.5% RSD over the injection volume range of 0.01 μL to 2000 μL. The unique flow design, combined with external needle wash and optional multiple wash solvents, virtually eliminates carryover, even of highly adsorbed compounds.

Specification

Condition: certified pre-owned
Detection type: Double-beam photometer
Light source: Deuterium lamp
Wavelength range: 190–600 nm
Short term noise (ASTM): ± 0.75 × 10-5 AU at 254 nm
Drift: 3 × 10-4 AU/hr at 254 nm
Linearity: > 2 AU (5%) upper limit
Wavelength accuracy: ± 1 nm
Band width: 6.5 nm typical
Flow cells: Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum; High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum; Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum; Semi-micro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
Control and data evaluation: Agilent ChemStation for LC
Analog outputs
Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Lowvoltages in major maintenance areas.
Features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.
Housing: All materials recyclable.

Features

Compact, benchtop design built on the "nearly perfect" 1100
Wide flow range up to 10 ml/min (at 200 bar) enables semi-preparative separation
Wide selection of autosamplers, full flexibility in injection volumes and sample containers
Programmable single lambda analysis, 1 signal, 13 Hz data rate
We provide training and installation packages

Related Products

GE AKTA Prime Liquid Chromatography System, The Latest LC Technology, GE AKTA (CAT#-STEM-CPO-0010-LGZ)
GE AKTA Prime Plus Liquid Chromatography System, Flow Rate 0.1 ml/min-50 ml/min, GE AKTA (CAT#-STEM-CPO-0011-LGZ)
GE AKTA Pure Preparative Chromatography System, UV Wavelength 280 nm, GE AKTA (CAT#-STEM-CPO-0012-LGZ)
GE AKTA Start Chromatography System, Flow Rate 0.5 – 5 ml/min, GE AKTA (CAT#-STEM-CPO-0013-LGZ)
GE Pharmacia AKTA Purifier 10, GE AKTA (CAT#-STEM-CPO-0014-LGZ)
GE Pharmacia AKTA Purifier 10 UPC, GE AKTA (CAT#-STEM-CPO-0015-LGZ)
Advertisement