Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1200 Series - G1315B HPLC Diode Array Detector, Agilent (CAT#: STEM-C-1156-LGZ)

Highlights

1. Access the spectral domain using superior 3D optics - simultaneous illumination, highest spectral resolution from 90 to 950 nm with highest intensity and lowest detection limit using combined deuterium and tungsten lamps, 1024 diode and 1-nm slit .
2. Programmable slits explore the spectral landscape for faster sample characterization - narrow settings focused on fine bands, or open the programmable slit for more light flux if higher sensitivity is required. The wide slit ensures the lowest baseline noise and the highest chromatographic signal-to-noise ratio. Store and report slit settings from 1 - 16 nm, along with GLP traceability of your raw data.
3. Convenient spectral storage and flexible viewing - easily stack spectra between runs or runs.

Cat Number: STEM-C-1156-LGZ

Application: For HPLC system.

Model: 1200 Series - G1315B

Add to Cart



Description

The manufacturer of Agilent 1200 Series - G1315B HPLC Diode Array Detector is Agilent. Model is 1200 Series - G1315B. The Agilent 1200 Series Diode Array Detector adds spectral acquisition to HPLC analysis. Validate separation quality with peak purity, multiple signal and spectral libraries - interactively or automatically run quantitatively with your analysis. Extended wavelength range from 190 to 950 nm with programmable slit for highest sensitivity or spectral resolution. and holmium oxide wavelengths to verify GLP compliance. The temperature management system ensures that the baseline stability is at an optimum level - even under harsh environmental conditions.

Specification

Condition: used
Detection type: 1024-element photodiode array
Light source: Deuterium and tungsten lamps
Wavelength range: 190 – 950 nm
Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
Drift: 2 × 10-3AU/hr at 254 nm
Linear absorbance Range: 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Wavelength bunching: 1 – 400 nm
Slit width: 1, 2, 4 , 8, 16 nm
Diode width: < 1 nm
Flow cells
Standard: 13 µL volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µL volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
High pressure: 1.7 µL volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
500 nano: 0.5 µL volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data Evaluation: Agilent ChemStation for LC
Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

Features

1. Access the spectral domain using superior 3D optics - simultaneous illumination, highest spectral resolution from 90 to 950 nm with highest intensity and lowest detection limit using combined deuterium and tungsten lamps, 1024 diode and 1-nm slit .
2. Programmable slits explore the spectral landscape for faster sample characterization - narrow settings focused on fine bands, or open the programmable slit for more light flux if higher sensitivity is required. The wide slit ensures the lowest baseline noise and the highest chromatographic signal-to-noise ratio. Store and report slit settings from 1 - 16 nm, along with GLP traceability of your raw data.
3. Convenient spectral storage and flexible viewing - easily stack spectra between runs or runs.
4. Verify Wavelength Accuracy to GLP - Automatic Holmium Oxide Filter Verify that your wavelength is indeed what the setpoint says.
5. Connect LC/MS - High pressure microfluidic cell for LC-MS applications with very small internal volume, use an Agilent ChemStation to acquire and view UV and MS spectral data.
6. Explore capillary HPLC flow rates as low as 5-µl/min using the new 500-nm liter flow cell. Compared with standard bore HPLC, the sensitivity is increased by 50 to 100 times.
7. Front access to lamp is easy and flow battery replacement is fast.
8. Low cost of ownership - long life deuterium lamp (>2000 hours), built-in diagnostic software.

Related Products

Agilent 1200 Series - G1315B HPLC Diode Array Detector, Agilent Technologies(CAT#-STEM-C-0068-LGZ)
Agilent 1200 Series - G1362A HPLC Refractive Index Detector, Agilent Technologies(CAT#-STEM-C-0073-LGZ)
Agilent 1260 Series - G1312B HPLC Binary Pump, Agilent Technologies(CAT#-STEM-C-0086-LGZ)
Agilent 1260 Series - G1315D HPLC Diode Array Detector, Agilent Technologies(CAT#-STEM-C-0087-LGZ)
Waters 2487 HPLC UV/VIS Detector, Waters Corporation(CAT#-STEM-C-0099-LGZ)
Alltech 3300 ELSD ELSD Controller, Grace(CAT#-STEM-C-0103-LGZ)