Echo 525® LIQUID HANDLER, Labcyte (CAT#: AM-AUTO-0171-LY)

Highlights

Designed for biochemical and genomic sample and reagent transfer
Improve data quality while saving on reagent costs
Reagent reservoir for larger volume reagent transfers

Cat Number: AM-AUTO-0171-LY

Application: Genomics research, Gene expression, Genotyping, Microbiome, RNAi, Single-cell genomics, Synthetic biology

Model: Echo 525® LIQUID HANDLER

Add to Cart



Description

The Echo 525® LIQUID HANDLER is manufactured by Labcyte. The flexibility, speed, accuracy and precision of this liquid handler enable researchers to build tests that are not possible with traditional liquid processors. The use of acoustic energy eliminates the boundaries of traditional tip and tip tool liquid processors. Transfer variable fluid heights and viscosities from one source plate for rapid analysis creation during a fluid transfer.

Specification

Drop volume: 25 nL
Volume transfer range: 25 nL – 5 µL one well to one well
Transfer accuracy: <10% deviation from target volume
Transfer precision: <8% CV
Reagents supported: PCR and qPCR reagents, synthetic biology reagents, NGS reagents, primers and probes, cell culture media, proteins, nucleic acids, up to 50% glycerol, serum, plasma, and antibodies
Source labware compatibility: Echo Qualified 384 Polypropylene, 384 Polypropylene Plus, Reservoir, Microplates
Destination labware compatibility: All Echo Qualified Microplates and most ANSI-compliant/SBS-standard microplates in 96-, 384-well formats 8 -16 mm in height. Use of 1536-well plates as destination plates is application dependent
Dimensions: 53.9 cm width x 68.3 cm depth x 92.5 cm height (21.2 x 26.9 x 36.4 inches)
Weight: 128 kg (283 lbs)
Working envelope: Additional 25.4 cm (10 inches) on top, 2.5 cm (1 inch) on sides, 7.6 cm (3 inches) at front, 30.5 cm (12 inches) at back
Electrical: AC 120V, 50/60 Hz, 10 A or AC 230V, 50/60Hz, 5 A
Operating temperature: 21°C ± 5°C (70°F ± 9°F)
Vacuum: House supply minimum 200 Torr (266 mbar, 22 inches Hg Vac) OR Standalone vacuum with surge tank, minimum pump speed 2.0 m3/hr (70.68 cu ft/hr), minimum pressure 100 Torr (133 mbar, 26 inches Hg Vac)
Fluid class calibration: No calibration needed

Features

Designed for biochemical and genomic sample and reagent transfer
Improve data quality while saving on reagent costs
Reagent reservoir for larger volume reagent transfers
Advertisement