Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Analysis Kinetics of Palytoxin by KinExA (CAT#: STEM-MB-0261-CJ)

Introduction

Palytoxin, PTX or PLTX is an intense vasoconstrictor, and is considered to be one of the most poisonous non-protein substances known, second only to maitotoxin in terms of toxicity in mice. Palytoxin occurs at least in tropics and subtropics where it is made by Palythoa corals and Ostreopsis dinoflagellates, or possibly by bacteria occurring in these organisms. It can be found in many more species like fish and crabs due to the process of biomagnification. It can also be found in organisms living close to palytoxin producing organisms like sponges, mussels, starfish and cnidaria. Palytoxin targets the sodium-potassium pump protein by locking it into a position where it allows passive transport of both sodium and potassium ions, thereby destroying the ion gradient that is essential for life.




Principle

Bio-Layer Interferometry (BLI) is an optical technique for measuring macromolecular interactions by analyzing interference patterns of white light reflected from the surface of a biosensor tip. BLI experiments are used to determine the kinetics and affinity of molecular interactions. In a BLI experiment, one molecule is immobilized to a Dip and Read Biosensor and binding to a second molecule is measured. A change in the number of molecules bound to the end of the biosensor tip causes a shift in the interference pattern that is measured in real-time.

Applications

Immunology/Inflammation, Toxicology

Procedure

1. Detect Buffers and prepare samples. BLI experiments are set up with one molecule immobilised on the surface of the biosensor (load sample) and a second molecule in solution (the analytical sample).
2. Fix the load sample on the biocompatible biosensor while the analytical sample is in solution.
3. The biosensor tip is immersed in the solution so that the target molecule begins to bind to the analysis sample.
4. Set up and run the BLI experiment. Molecules bound to or dissociated from the biosensor can generate response curves on the BLI system; unbound molecules, changes in the refractive index of the surrounding medium or changes in flow rate do not affect the interferogram pattern.
5. Collect and analyse data on the BLI's system.

Materials

• Equipment: ForteBio Bio-Layer Interferometry (BLI)
• Sample Type: DNA, RNA, Protein, Antibodies, Peptides, Small Molecules
Advertisement