Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Beckman Coulter LS6500 Liquid Scintillation Counter, Ambient Temperature Range 15 – 35 °C, Beckman Coulter (CAT#: STEM-AIAEPO-0201-LGZ)

Highlights

32,768-channel multi-channel analyzer
Advanced photomultiplier design
Interlocking Lead Shielding

Cat Number: STEM-AIAEPO-0201-LGZ

Application: For biological research.

Model: LS6500

Add to Cart



Description

The Beckman LS-6500 system is equipped with a 32,678-channel analyzer, providing an effective resolution of 0.06 keV to obtain accurate results in a variety of samples. The patented H-Number Plus external quench monitor (H-Number Plus) is installed into the system to provide accurate decomposition per minute (DPM) calculations and automatic quench compensation. Both measurements are independent of sample volume or cocktail composition. This feature is also the basis for instrument calibration, color detection and correction, two-phase monitoring, unquenched window determination, and multi-label DPM quenching curves.

The LS 6500 counter lifts the sample plastic rack into the sample chamber instead of lowering the compartment into the sample chamber. This design prevents possible contamination of the chamber with dust or liquid residue. As for system operation, the combination of easy-to-use menus, context-sensitive help screens and 50 user programs make the LS 6500 a one-button system.

System Plus and System Advantage models are equipped with powerful analysis tools. Units come with a single or dual label DPM, a proprietary H-Number Plus quench monitor, and the Versa-Rack™ bottle system, allowing mixing of 20ml and 7ml vials. Enhancement packages and other features can be added later to meet emerging laboratory needs. The capacity of the instrument is 336 standard bottles (20ml), or 648 vials (7ml) or a combination thereof.

Specification

Condition: certified pre-owned
Resolution: 32,768 channels, 0.06 keV per channel
Reproducibility: +/- 1% Counting Efficiency
Maximum Count Rate: Total Singles: 26 x 10^6 CPM; 3H Window: 10 x 10^6 CPM; 14C Window: 13 x ^6 CPM; Above 14 C Window: 5 x ^6 CPM
Power Requirements: 120 / 240V / BTU HR with 50/60 Hz
Instrument: 3A / 1.5A / 1230
Temperature: 7.5A / 3.8A / 3060
Inrush Current: 5A at 120V, 2.5A at 240V
Power Failure Recovery: System returns to a disrupted Automatic Count with fully charged battery
Dimensions (W x H x D / Weight): Instrument: 91.4 x 67.3 x 80 cm / 210 kg; Refrigeration Acc.: 35.5 x 56 x 73.7 cm / 45.4 kg; Printer: 39 x 10 x 30.5 cm / 5 kg
Ambient Temperature Range: 15 – 35°C
Maximum Relative Humidity: 85%
Ambient Temperature Range: 15°C to 30°C
Maximum Pull Down Time: 8 Hours
Set Point 1: 12°C +3°C
Set Point 2: 15°C +3°C
Set Point 3: 18°C +3°C
Efficiency: 2H: >/= 60% in a wide window; 14C: >/= 95/5 in a wide window

Features

32,768-channel multi-channel analyzer
Advanced photomultiplier design
Interlocking Lead Shielding
User selectable output format
Serving a full set of counting cocktails
Includes full service installation and basic user training

Related Products

Packard Tri-Carb Liquid Scintillation Counter, Bi-Directional Conveyor Track, Packard Cobra (CAT#-STEM-AIAEPO-0205-LGZ)
Perkin Elmer 1450 Microbeta Classic, Password Protection, Perkin Elmer (CAT#-STEM-AIAEPO-0206-LGZ)
Perkin Elmer 2450 Microbeta2, Solid Scintillator, Perkin Elmer (CAT#-STEM-AIAEPO-0207-LGZ)
Perkin Elmer Quantulus GCT Liquid Scintillation Counter, Energy Range 0–2,000 keV, Perkin Elmer (CAT#-STEM-AIAEPO-0208-LGZ)
Perkin Elmer Tri-Carb 4810TR Liquid Scintillation Counter, 100-240 Vac, Perkin Elmer (CAT#-STEM-AIAEPO-0209-LGZ)
Perkin Elmer Tri-Carb 4910TR Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#-STEM-AIAEPO-0210-LGZ)
Advertisement