Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Beckman Coulter TLS 55 Rotor, Beckman Coulter (CAT#: STEM-LC-1635-LGZ)

Highlights

1. Main uses: RNA spheroidization in 2-3 hours; subcellular division in sucrose gradients; protein separation in sucrose gradients. Notably, non-precipitating solutions with densities up to 1.7 g/mL can be run on this rotor without the rotor speed being reduced.
2. For use with the Optima MAX-xp Benchtop Ultracentrifuge, Optima TLX Personal Micro Ultracentrifuge, Optima MAX High Capacity Personal Micro Ultracentrifuge, and the discontinued TL-100 and Optima TL Micro Ultracentrifuges.

Cat Number: STEM-LC-1635-LGZ

Application: For RNA pelleting in 2-3 hours; subcellular fractionation in sucrose gradients; protein separations in sucrose gradients.

Model: TLS 55

Add to Cart



Description

The manufacturer of Beckman Coulter TLS 55 Rotor is Beckman Coulter. Model is TLS 55. TLS-55 Swinging-Bucket Rotor Assembly, made of titanium, with 4 titanium buckets.

Specification

Condition: used
Maximum speed: 55,000 RPM
Density rating at maximum speed: 1.7 g/mL
Relative Centrifugal Field at maximum speed
at rmax (76.5 mm): 259,000 ´ g
at rav (59.4 mm): 201000 ´ g
at rmin (42.2 mm): 143,000 ´ g
k factor at maximum speed: 50
Nominal tube dimensions (largest tube): 11 x 34 mm
Nominal tube capacity (largest tube): 2.2 mL
Nominal rotor capacity: 8.8 mL
Approximate acceleration time to maximum speed (fully loaded): 8 min
Approximate deceleration time from maximum speed (fully loaded): 4 1/2 min
Weight of fully loaded rotor: 0.8 kg (1.69 lb)
Rotor body material: aluminum
Bucket material: titanium

Features

1. Main uses: RNA spheroidization in 2-3 hours; subcellular division in sucrose gradients; protein separation in sucrose gradients. Notably, non-precipitating solutions with densities up to 1.7 g/mL can be run on this rotor without the rotor speed being reduced.
2. For use with the Optima MAX-xp Benchtop Ultracentrifuge, Optima TLX Personal Micro Ultracentrifuge, Optima MAX High Capacity Personal Micro Ultracentrifuge, and the discontinued TL-100 and Optima TL Micro Ultracentrifuges.

Related Products

Beckman Coulter JA-20 Rotor, Beckman Coulter(CAT#-STEM-LC-1561-LGZ)
Beckman Coulter JA-20.1 Rotor, Beckman Coulter(CAT#-STEM-LC-1562-LGZ)
Beckman Coulter JA-21 Rotor, Beckman Coulter(CAT#-STEM-LC-1563-LGZ)
JLA 16.250 Rotor, Beckman Coulter(CAT#-STEM-LC-1564-LGZ)
Beckman Coulter JS 4.2 Rotor, Beckman Coulter(CAT#-STEM-LC-1566-LGZ)
Beckman Coulter NVT 100 Rotor, Beckman Coulter(CAT#-STEM-LC-1594-LGZ)