Bio-Rad Bio-Plex Luminex 200 Suspension Array Analyzer Unit4 - AV In Walpole, MA, USA, model Bio-Plex, is manufactured by Bio-Rad biotechnology & life science. Here is a Bio-Rad Bio-Plex Luminex 200 Suspension Array Analyzer Unit4 Predecessor to: Current model Condition: This Bio-Plex 200 Suspension Array Analyzer is in good working order. Testing we performed: The Bio-Plex 200 Suspension Array Analyzer passed all tests and was found to be fully functional: Tested operation software communication: PASSED Tested operation of pneumatic pump and set air pressures to specification: PASSED Tested operation of probe and probe actuator: PASSED Tested operation of SD sheath fluid module: PASSED Tested operation sheath fluid valves in system: PASSED Tested operation of XYP microplate stage: PASSED Performed calibration procedure for Cal1 and Cal2: PASSED Performed all cleaning and flushing protocols (Prime, Wash, Sanitize, Alcohol Flush, Soak): PASSED Performing the calibration procedure and getting a passing result verifies that all the subsystems are operating together. The equipment requires the proper operation of the XYP stage, probe, probe flow control valve, probe actuator, syringe pump operation, and valving. The pressures and fluidics must operate in acceptable ranges so that the calibration beads do not flow too fast or slow through the flow cell. The lasers must align with the flow cell so that the beads can fluoresce adequately to be seen by the detectors. Then the detectors need to be operating correctly to receive the fluorescent light and convert it to an electrical signal to be processed by the software on the computer to provide a passed calibration result. Based on our tests, we are confident this Bio-Plex 200 Suspension Array Analyzer operates as designed. System consists of: Luminex BioRad BioPlex 200 XYP Microplate Stage SD Sheath Delivery system Computer running BioPlex Manager software ver6 with a usb licence dongle Communication and power cables, and hoses. Please note that the sheath fluid and waste bottles may differ in appearance; we get them from various suppliers. Configuration and Setup: Number of Lasers: 2 Laser Type: Reporter Laser 532nm and Classification Laser 635nm System checks for type of bead and if bead has analytes attached to it Sample Handling: system uses 96 well-plates Sample Volume: 20 - 200uL Video Description: The video gives an overview of the Bio-Plex 200 Suspension Array Analyzer, and also performs functionality. Documentation: Datasheet: N/A Brochure: https://drive.google.com/file/d/1YCPJbe0mZ5SDr9U38-5hcCz2C-FCIpj6/view?usp=sharing Manual: https://drive.google.com/file/d/1Fa5-hfArVaD-hy9KXCkvJzeET7NeOXBU/view?usp=sharing This will ship via freight. Please contact us with your zip code to obtain shipping quote.
Specification
Condition: Used Height: 7.00 Width: 7.00 Depth: 7.00 Weight: 4.00
Related Products
BIO-RAD PHD SY(CAT#: STEM LAB ANALYZER IFA And EIA Instrumentation, 100 to 240 volts In Arcade, NY, USA (CAT#: STEM-CTEPO-0631-YJL) Bio-Rad PhD System Lab Analyzer In Bloomington, MN, USA (CAT#: STEM-CTEPO-0632-YJL) Bio-Rad Trans-blot In Rocklin, CA, USA (CAT#: STEM-CTEPO-0633-YJL) Bio Rad PhD lx (426-0401) In Marysville, WA, USA (CAT#: STEM-CTEPO-0634-YJL) Bio-Rad general medical equipment (CAT#: STEM-CTEPO-0635-YJL) Bio-Rad Luminex, 60 µl/sec In Woonsocket, RI, USA (CAT#: STEM-CTEPO-0640-YJL)