The manufacturer of the Draeger Medical Isolette TI500 Transport Incubatoris Dräger. The Drager Isolette TI500 incubator is a self-contained, mobile, intensive care unit. Consistent air temperature is essential to the health of a premature infant. the TI500 incubator features a double wall design which reduces radiant heat loss from the infant during transport between departments or between hospitals. Humidity is extremely important, especially for babies less than 26 weeks in gestational age. An integral humidity pad helps minimize the infant's evaporative heat loss by providing 50 to 70 percent humidity in the patient-hood for up to 12 hours. The controller features a display that is easy to read at any angle during transport. The product is located in Twinsburg, OH, USA.
Specification
Condition: Certified Pre-owned Material: Isolette TI500 Common name: Transport Incubator Powers on: Yes Includes power cords: Yes Functional condition: Untested Cosmetic condition: Good Dimensions Height: 20 in (50.8 cm) Width: 20.8 in (52.7 cm) Length: 37.8 in (95.9 cm) Weight: 108.5 lbs (49.2 kg) Distance From Vertical Hood to Mattress: Low Hood 8.25 in (21 cm) General O2 Concentration Range: 21% to 58% minimum Humidity Capacity: 50% to 70% Noise Level: <60 dBA Performance Temperature Set Range: 22.0 °C - 38 °C (71 °F - 100 °F) Temperature Rise Time: 30 minutes Temperature Variability: ≤1.0 °C Temperature Overshoot: ≤2.0 °C Temperature Uniformity: ≤1.0 °C Correlation of Display Temperature to Set Point at Temperature Equilibrium: ≤ 2.0 °C in l0-20 °C ambients ≤1.5 °C in 20-30 °C ambients Humidity Pad: Holds 400 ml.(14 oz) sterile distilled water with no significant spillage for up to 45° tilt in either direction. Air Filter: Removes >99% of airborne particles greater than 0.5 micron diameter Relative Humidity: 50 to 70% for 10-12 hours using humidity pad Check Calibration Key: 36.0 ° ± 0.l °C Battery Incubator: 1 battery standard (2nd optional) Type: Vented rechargeable, 12 Vdc, 24 AH gel-type battery (lead acid) Battery rating: Incubator maintains a differential of 25 °C (77 °F) between ambient and set point for 90 minutes on 1 battery or 180 min.on 2 batteries at full heater power Life expectancy: 200 complete charge/discharge cycles minimum Charge time: 10 hours per battery from full discharge
Features
Double wall Skin temperature probe O2 inlet Examination lamp 2 access doors 2 disposable infant restraint straps 1 Iris port 2 Quiet Touch (QT) port doors 6 tubing ports Locking power control receptacles DC cable 2D or 2E size tank mount
Related Products
Draeger Medical C2000 Infant Incubator, Dräger Draeger Medical Vapor 19.1 Isoflurane Vaporizer, Dräger Drager Caleo 2M50555-34 Infant Incubator, Dräger