Draeger Medical Isolette TI500 Transport Incubator, Dräger (CAT#: STEM-CCPO-0201-ZJF)

Highlights

Double wall
Skin temperature probe
O2 inlet

Cat Number: STEM-CCPO-0201-ZJF

Application: For cell culture in controlled environment

Model: Isolette TI500

Add to Cart



Description

The manufacturer of the Draeger Medical Isolette TI500 Transport Incubatoris Dräger.
The Drager Isolette TI500 incubator is a self-contained, mobile, intensive care unit. Consistent air temperature is essential to the health of a premature infant. the TI500 incubator features a double wall design which reduces radiant heat loss from the infant during transport between departments or between hospitals. Humidity is extremely important, especially for babies less than 26 weeks in gestational age. An integral humidity pad helps minimize the infant's evaporative heat loss by providing 50 to 70 percent humidity in the patient-hood for up to 12 hours. The controller features a display that is easy to read at any angle during transport.
The product is located in Twinsburg, OH, USA.

Specification

Condition: Certified Pre-owned
Material: Isolette TI500
Common name: Transport Incubator
Powers on: Yes
Includes power cords: Yes
Functional condition: Untested
Cosmetic condition: Good
Dimensions
Height: 20 in (50.8 cm)
Width: 20.8 in (52.7 cm)
Length: 37.8 in (95.9 cm)
Weight: 108.5 lbs (49.2 kg)
Distance From Vertical Hood to Mattress: Low Hood 8.25 in (21 cm)
General
O2 Concentration Range: 21% to 58% minimum
Humidity Capacity: 50% to 70%
Noise Level: <60 dBA
Performance
Temperature Set Range: 22.0 °C - 38 °C (71 °F - 100 °F)
Temperature Rise Time: 30 minutes
Temperature Variability: ≤1.0 °C
Temperature Overshoot: ≤2.0 °C
Temperature Uniformity: ≤1.0 °C
Correlation of Display Temperature to Set Point at Temperature Equilibrium: ≤ 2.0 °C in l0-20 °C ambients ≤1.5 °C in 20-30 °C ambients
Humidity Pad: Holds 400 ml.(14 oz) sterile distilled water with no significant spillage for up to 45° tilt in either direction.
Air Filter: Removes >99% of airborne particles greater than 0.5 micron diameter
Relative Humidity: 50 to 70% for 10-12 hours using humidity pad
Check Calibration Key: 36.0 ° ± 0.l °C
Battery
Incubator: 1 battery standard (2nd optional)
Type: Vented rechargeable, 12 Vdc, 24 AH gel-type battery (lead acid)
Battery rating: Incubator maintains a differential of 25 °C (77 °F) between ambient and set point for 90 minutes on 1 battery or 180 min.on 2 batteries at full heater power
Life expectancy: 200 complete charge/discharge cycles minimum
Charge time: 10 hours per battery from full discharge

Features

Double wall
Skin temperature probe
O2 inlet
Examination lamp
2 access doors
2 disposable infant restraint straps
1 Iris port
2 Quiet Touch (QT) port doors
6 tubing ports
Locking power control receptacles
DC cable
2D or 2E size tank mount