Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Dual Channel Photometer, Optical Building Blocks, a Division of HORIBA Scientific (CAT#: STEM-LE-0801-LC)

Highlights

Cheap and versatile — OBB photometers are versatile and can be adapted to microscopes of any manufacturer through a standard C-mount mount on the discharge port. You will never be tied to a specific range of manufacturers, so the cost is lower.
Adjustable detection range-users can intuitively see and select the desired detection field of view.
Eyepiece-allows the user to intuitively identify the area to be measured.

Cat Number: STEM-LE-0801-LC

Application: Emission shifted dies, Multi dies detection, Fluorescence Microscopy, Quantitative FRET, FRAP, FISH, Ca++, Fluo-3, Fluo-4, INDO-1

Add to Cart



Description

The 4301 photometer is equipped with an eyepiece to visually observe what will be detected on the microscope stage. By adjusting the pair of vertical and horizontal apertures in the field of view, it is possible to isolate a small number of cells, a single cell or even a part of the cell for measurement. The diachronic beam splitter is placed in the photometer to direct the appropriate emission wavelength to each detector for simultaneous double detection. The duration beam splitter can be easily changed to select the desired emission wavelength.

Specification

Type:Microscope photometer
Wavelength Range:185 to 900 nm
Resolution:Bandwidth filter dependent
Optical System:PMT photometer
Dimensions:(WxDxH) 95 x 95 x 183 mm
Connections:BNC
Mode(s):Analog or Photon Counting PMT
Data Acquisition Rate:1 point/100 sec to 500,000 points/sec
Bandwidth:Bndwidth filter dependent
Wavelength(s):185 to 900 nm

Features

Cheap and versatile — OBB photometers are versatile and can be adapted to microscopes of any manufacturer through a standard C-mount mount on the discharge port. You will never be tied to a specific range of manufacturers, so the cost is lower.
Adjustable detection range-users can intuitively see and select the desired detection field of view.
Eyepiece-allows the user to intuitively identify the area to be measured.
Wavelength selection-use a cheap standard 1 inch filter for wavelength selection.
Analog detection mode-high sensitivity and maximum dynamic range.
Wide spectral bandwidth-from UV to NIR detection capabilities.
Dual wavelength detection-two wavelengths can be detected simultaneously.
Complete software-for data collection and analysis.

Related Products

PMT Photometers, Tri-Channel Photometer