Fluke PM2811 In Rochester, NY, USA, model PM2811 is manufactured by Fluke power supplies. The Fluke 2811 Programmable Power Supply was created with automated testing in mind. The GPIB/IEEE-488 interface, output power module and output metering facilities are built in, taking up only two engineering units of rack height. The full rack-width models come equipped with rack mount ears for easy installation in a standard 19-inch rack. The front panel allows full access to all instrument functions, including voltage and current readback. A sequence of front panel settings can be created with the AUTOSTEP mode, quickly creating an automated test pattern of user-defined voltages and currents with no need for a controller. The optional front panel output gives the user easy access to both the power output connections and the sense lines; great for prototyping and temporary setups.
Specification
Condition: Used Readback accuracy: (referred to the output terminals) OUTPUT module: 30 V - 10 A - 60 W Output Voltage range: 0 to 30 V Output Current range: 0 to 10 A Output Power: 60 W Overvoltage protection range: 2 to 32 V Accuracy: (at calibration temperature) Output Voltage: +/- 0.04 % of setting: + 10 mV Output Current: +/- 0.1 % of setting + 50 mA Over Voltage Protection: +/- 0.5 % of setting: + 150 mV Temperature: coefficient Output Voltage: (0.016 % of setting + 2 mV)/K Output Current: (0.05 % of setting + 2 mA)/K Long term drift: (in an 8 hour period) Output Voltage: 0.04 % of setting + 5 mV Output Current: 0.05 % of setting + 10 mA Programming Resolution: (12bit) Output Voltage: 7.5 mV/LSB Output Current: 2.5 mA/LSB Over Voltage Protection: 7.5 mV/LSB Source Effect: (for any line voltage change within rating) Voltage: +/- (0.01 % of setting + 2 mV) Current: +/- (0.02 % of setting + 2 mA) Load Effect: (load change 10 % to 90 % or 90 % to 10 % full load) Constant Voltage: +/- (0.01 % of setting + 5 mV) Constant Current: +/- (0.02 % of setting + 5 mA) Output Noise: (PARD) Constant Voltage pp/rms: 15 mV/3 mV Constant Current rms: 10 mA Accuracy: (at calibration temperature) Voltage: +/- (0.05 % + 25 mV) Current: +/- (0.1 % + 30 mA) Measuring Resolution: (12 bit) Voltage resolution to interface: 7.5 mV Current resolution to interface: 2.5 mA Voltage resolution to display: 10 mV Current resolution to display: 10 mA Max. Current at Reverse voltage: 10 A REMOTE SENSE: > 0.25 Volt drop per lead: (at open sense connections, the output voltage will not be more than 3 V above the programmed value) DYNAMIC OPERATION: I=1 A between 1 and 10A between 0.5 and 5A between 1 and 10A Settling band: +/- 50 mV dI/dt: < 1 A/s Overshoot: < 150 mV Recovery time: < 1 ms Programming response: (measured with resistive load) Up (0 V to max. output): 100 ms @ 2 A Up (0 V to max. output): 50 ms @ (no load) Down (max.output to 1 V): 100 ms @ 2 A Down (max.output to 1 V): 50 ms @ (no load) Range: 50 ms to 60 s Resolution: 1 ms Default: 50 ms Step Interval time: up to 60 s GPIB
Features
Load cross regulation Negligible for both voltage and current Switching Frequency approx. 20 kHz approx. Reprogramming delay
Related Products
Fluke PM 2811 In New Smyrna Beach, FL, USA (CAT#: STEM-GLEPO-1048-YJL) Fluke PM 2813 In New Smyrna Beach, FL, USA (CAT#: STEM-GLEPO-1049-YJL) Fluke PM 2812 In New Smyrna Beach, FL, USA (CAT#: STEM-GLEPO-1050-YJL) Fluke PM 2832 In New Smyrna Beach, FL, USA (CAT#: STEM-GLEPO-1051-YJL) Fluke PM 2831 In New Smyrna Beach, FL, USA (CAT#: STEM-GLEPO-1052-YJL) Fluke V3000 In Orlando, FL, USA (CAT#: STEM-GLEPO-1098-YJL)