Gas Chromatography, Model GC1290, DRAWELL (CAT#: STEM-C-0002-CJ)

Highlights

Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”).
Advanced built-in data acquisition system, supporting real-time instrument status monitoring, detection signal acquisition, and PC control.

Cat Number: STEM-C-0002-CJ

Application: Used to analyze the thermal stable organic compounds in soil, such as volatile organic compounds, organic chlorine, organic phosphorus, polycyclic aromatic hydrocarbons, phthalates, etc.

Model: GC1290

Add to Cart



Description

Gas Chromatography is a kind of instrument for qualitative and quantitative analysis of multicomponent complex mixture by using chromatographic separation technology and detection technology. Generally, it can be used to analyze the thermal stable organic compounds in soil, such as volatile organic compounds, organic chlorine, organic phosphorus, polycyclic aromatic hydrocarbons, phthalates, etc.

Specification

Description:EPC(electronic pneumatic control) 7 inch touch screen display
Sample Introduction System: sample injector and evaporation chamber
Column Oven: Temperature range:Ambient temperature +7℃ ~ 400℃ (in 1℃incremen); Temperature accuracy:± 0.02℃; Cooling time:350℃〜100℃≤3min; 400℃ to 50℃ in 8-10 min at 25℃ ambient ;Programmed temperature setting:0.1℃~40℃/min (in 1℃ increment); Program ramps:20 ramps in total (10 ramps available with control workstation; Size (L*W*H):284*280*241mm(inside) 340*345*281mm(outside)
Flame Ionization: Detection limit ≤8×10- 12 g/s (n-hexadecane)
Thermal Conductivity Detector(TCD): Drift ≤1.5×10- 13 A/h Noise≤3×10- 14 A; Linearity range≥106
Flame Photometric Detector(FPD): Detection limit ≤8×10- 13 g/s(P) ; ≤8×10- 11 g/s(S); Drift ≤2×10- 11 A/30min; Baseline noise ≤5×10- 12 A

Features

Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”).
Advanced built-in data acquisition system, supporting real-time instrument status monitoring, detection signal acquisition, and PC control.
Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with the automated back-door opening. (400℃ to 50℃ in 6 min at 25℃ ambient).
Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures).
Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards.