Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Hermle Z446 Universal Centrifuge, Hermle (CAT#: STEM-LC-1654-LGZ)

Highlights

1. Aircraft grade, high-quality alloy structure, 4 × 750 mL swing-out rotors can withstand centrifugal force above 4500 x g, fully loaded with 28 × 50 mL, 68 × 15 mL tubes, and 20 × microplates.
2. Advanced microprocessor control allows instant rotor identification, automatic conversion of rotational speed to the relative gravity (rcf), preventing the user from setting the speed beyond the capacity of the installed rotor.
3. In addition to retrieving saved programs, the front panel is easy to use, allowing you to adjust acceleration/deceleration rates and change the end-of-run alarm sound.

Cat Number: STEM-LC-1654-LGZ

Application: For concurrent Separation, Sample Preparation, etc.

Model: Z446

Add to Cart



Description

The manufacturer of Hermle Z446 Universal Centrifuge is Hermle. Model is Z446. These high volume centrifuges Z446 and Z446 K achieve a throughput of 68 x 15 mL conical tubes or 28 x 50 mL conical tubes at max. RCF is 3434/4346 xg. A maximum angle rotor is available for higher speeds. RCF is 14532/16022 xg, 10 x 50 mL.

Specification

Condition: used
Max. Speed: 16000 rpm
Max. RCF: 24325 x g
Max. Volume: 4 x 750 mL
Speed range: 200 - 16000 rpm
Running time: 59 min 50 s / 10 s increments, 99 h 59 min / 1 min increments
Dimensions (WxHxD): 54 cm x 39 cm x 67 cm
Weight: 79 kg

Features

1. Aircraft grade, high-quality alloy structure, 4 × 750 mL swing-out rotors can withstand centrifugal force above 4500 x g, fully loaded with 28 × 50 mL, 68 × 15 mL tubes, and 20 × microplates.
2. Advanced microprocessor control allows instant rotor identification, automatic conversion of rotational speed to the relative gravity (rcf), preventing the user from setting the speed beyond the capacity of the installed rotor.
3. In addition to retrieving saved programs, the front panel is easy to use, allowing you to adjust acceleration/deceleration rates and change the end-of-run alarm sound.
4. Rotor exchange is simple and takes less than a minute. The included rotor wrench can be used to loosen and install all rotors. Once the rotor is placed on the motor shaft, the identification process starts and the installed rotor code is displayed on the backlit LCD display.

Related Products

Beckman Coulter Allegra 6R Benchtop Refrigerated Centrifuge, Beckman Coulter(CAT#-STEM-LC-1494-LGZ)
Beckman Coulter Allegra X-12R Benchtop Refrigerated Centrifuge, Beckman Coulter(CAT#-STEM-LC-1495-LGZ)
Beckman Coulter Allegra X-22 Benchtop Centrifuge, Beckman Coulter(CAT#-STEM-LC-1496-LGZ)
Beckman Coulter Allegra X-22R Benchtop Refrigerated Centrifuge, Beckman Coulter(CAT#-STEM-LC-1497-LGZ)
Shandon Cytospin 3 Cytocentrifuge, Shandon(CAT#-STEM-LC-1507-LGZ)
Precision Durafuge 300 Benchtop Centrifuge, Thermo Fisher Scientific(CAT#-STEM-LC-1510-LGZ)
Advertisement