Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

HLD MD30 Mobile Dry Helium Leak Detector (CAT#: AM-LE-0581-Y)

Highlights

• Six different application setup wizards help you configure the instrument correctly for optimal performance
• The touch screen interface is larger, more durable, and more responsive, and can be rotated 180° for easy viewing
• More concise and intuitive user interface

Cat Number: AM-LE-0581-Y

Application: The Agilent HLD MD30 dry leak detector uses a mass spectrometer designed to detect helium, using helium as a tracer gas to locate and/or measure small leaks in enclosed equipment or systems.

Add to Cart



Specification

User interface: 21 cm (8.4 inches) touch screen
Foreline pump and pumping rate: TriScroll 620 dry scroll pump, 30 m3/h (18 cfm)
The patented double pump design can realize rapid purification and background suppression.
Sensitivity: 5 × 10^-12 mbar•L/s, 5 × 10^-12 atm•cc/s, 5 × 10^-13 Pa•m3/s
Maximum test interface pressure:
13 mbar (10 Torr, 1333 Pa)
200 mbar (150 Torr, 20000 Pa), coarse leak mode
Calibration:
-Automatic inside and outside
-Ability to check calibration during testing
Communication function: Analog output and serial communication are standard configuration. Optional independent IO interface.

Features

• Six different application setup wizards help you configure the instrument correctly for optimal performance
• The touch screen interface is larger, more durable, and more responsive, and can be rotated 180° for easy viewing
• More concise and intuitive user interface
• The start-up wizard can help the user to set up the instrument after the power is turned on for the first time
• Enhanced chart function: It is convenient to carefully check the data enlargement mode, the setting value of the color mark, and record the time curve of the leak rate and pressure
• A larger work surface provides ample space for components and tools to be tested
• The improved shutdown procedure can put the leak detector in a vacuum environment and protect the turbo molecular pump
• Greater mobility helps easier access to narrow service areas and ranges in semiconductor production lines or other production environments
• Dry-type vacuum pumps can prevent the pump oil from contaminating the tested parts and systems