Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

HLD MD30 Mobile Dry Helium Leak Detector (CAT#: AM-LE-0581-Y)

Highlights

• Six different application setup wizards help you configure the instrument correctly for optimal performance
• The touch screen interface is larger, more durable, and more responsive, and can be rotated 180° for easy viewing
• More concise and intuitive user interface

Cat Number: AM-LE-0581-Y

Application: The Agilent HLD MD30 dry leak detector uses a mass spectrometer designed to detect helium, using helium as a tracer gas to locate and/or measure small leaks in enclosed equipment or systems.

Add to Cart



Specification

User interface: 21 cm (8.4 inches) touch screen
Foreline pump and pumping rate: TriScroll 620 dry scroll pump, 30 m3/h (18 cfm)
The patented double pump design can realize rapid purification and background suppression.
Sensitivity: 5 × 10^-12 mbar•L/s, 5 × 10^-12 atm•cc/s, 5 × 10^-13 Pa•m3/s
Maximum test interface pressure:
13 mbar (10 Torr, 1333 Pa)
200 mbar (150 Torr, 20000 Pa), coarse leak mode
Calibration:
-Automatic inside and outside
-Ability to check calibration during testing
Communication function: Analog output and serial communication are standard configuration. Optional independent IO interface.

Features

• Six different application setup wizards help you configure the instrument correctly for optimal performance
• The touch screen interface is larger, more durable, and more responsive, and can be rotated 180° for easy viewing
• More concise and intuitive user interface
• The start-up wizard can help the user to set up the instrument after the power is turned on for the first time
• Enhanced chart function: It is convenient to carefully check the data enlargement mode, the setting value of the color mark, and record the time curve of the leak rate and pressure
• A larger work surface provides ample space for components and tools to be tested
• The improved shutdown procedure can put the leak detector in a vacuum environment and protect the turbo molecular pump
• Greater mobility helps easier access to narrow service areas and ranges in semiconductor production lines or other production environments
• Dry-type vacuum pumps can prevent the pump oil from contaminating the tested parts and systems

Related Products

HLD BD15 Bench Dry Helium Leak Detector from Agilent Technologies
HLD BD30 Bench Dry Helium Leak Detector from Agilent Technologies
PHD-4 Sniffer from Agilent Technologies

Other recommended products

Advertisement