From routine tests to specific tests, execute them on a single system
55 airborne inspections Innovative cassette format Integration Workstations and Validation Workstations touch screen See your workflow in real time
General Description Analysis method type: Spectrophotometry: Colorimetry and Turbidimetry Potentiometric assays: direct (serum or plasma) and indirect (urine) Up to 55 assays on board Optional ISE modules (Na+, K+, Cl-) Maximum throughput: 420 tests/hour CE Mark
Sample Handling Sample capacity: 6 racks, 10 sample positions, main tubes or cups continuous loading Positive sample identification: integrated barcode reader and tube presence detector Sample Integrity: Level, Shock and Clot Detection Sample collection formats: 0.7, 4, 5, 7 and 10ml (diameter: 16mm) Specimens: Serum, plasma, urine, cerebrospinal fluid, whole blood, homogeneous liquid Sample volume: 2 ~ 380 μL Automatic sample dilution: 1/2 to 1/22500 ISE: 20 μL (indirect) or 60 μL (direct) Automatic post concentration: from x2.0 to x10.0 Rerun automatically
Calibrator/Control Processing Position of the calibrator/control sample or reagent tray Automated standard dilution series: Dilution Factor: Mainly Direct 1/2 - 1/150 Dilution Factor: Main Indirect 1/2 - 1/1508
Reagent handling 52 reagent positions: 44 in an enclosed refrigerated area (2-10°C) 8 at room temperature Positive Reagent Identification: Integrated Barcode Reader Reagent Probes: Level Detection and Preheating Reagent Management & Cassettes: Automated Reagent On-Board Stability Check Plus Test Countdown & Automatic Backup Reagent capacity: 2 ~ 600 μL
Reaction System Reaction volume: 150 ~ 600 μL Reaction temperature: 37℃ air bath Photometer reaction cycle: 12 seconds Stir with a Teflon-coated stirrer Response time: 1 to 100 cycles Disposable acrylic test tube Automatic tube change Tube capacity: 36 segments (432 tubes) 7 Comprehensive calculation algorithm
Specification
Condition: certified pre-owned Physical System Size: 101 x 71 x 63cm (W x L x H) System Weight: 120 kg External Cooling Unit Size: 29 x 42 x 40cm (W x L x H) External Cooling Unit Weight: 35 kg Printer: Printer Sound level: < 60 dBa Operating temperature: from 15 to 32°C Operating Humidity: from 20 to 85% Total Power Requirements (with Printer): 1000 VA Water: De-ionized/Distilled Water – 10L Tank Water specifications: Resistivity > 5 MegOhms; Conductivity < 0.2 µS/cm Computer & Software Operating system: Windows 10 Data processing: 12 inch Color LCD Touch Screen; Database Capacity: 100,000 results; Processor: 600 MHz; RC 232C: Patient results, QC to LIS with ASTM protocol Integrated Validation Station Quality Control Management: Levey Jennings, Automatic QC, Default controls and Westgard rules Logs: Reagents, Quality Control, Calibrations; Applications, Maintenance, Sequencing, Flags and Alarms Export of archived data and Quality Control data (QCP): USB key Audible alarms Interactive Help: HTML Format Optical System Tungsten-halogen Lamp Measurement Principle: Bi-chromatic light absorbance; Choice of 15 wavelengths from 340 to 700 nm; Wavelength selection with holographic grating technology Sensor: Photo diode array Optical Linearity: 2.5 A. at 340mm; 3.0 at other wavelengths