Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Packard TopCount NXT Scintillation Counter, Hologram ODBC, Packard Cobra (CAT#: STEM-AIAEPO-0204-LGZ)

Highlights

Low flicker and glow background.
Efficient counting in opaque microplates.
Compatible with filter plates and pads.

Cat Number: STEM-AIAEPO-0204-LGZ

Application: For biological research.

Model: TopCount NXT

Add to Cart



Description

Packard TopCount NXT is a high performance scintillation counter with high sampling capacity and throughput. This high-efficiency model provides low background counts for beta, gamma, and glow-emitting samples in 24, 96, and 384-well microplates and microvials.

Each TopCount scintillation counter is equipped with unique counting technology to ensure superior performance. This patented single photomultiplier tube (PMT) time-resolved counting method, when used with opaque plates, results in virtually crosstalk-free counting.

High sensitivity was achieved using time-resolved liquid scintillation counting (TR-LSC) technique. The method distinguishes background from true counts by analyzing the decay period of each scintillation event, resulting in high signal-to-noise ratio, superior sensitivity, and linearity over a wide dynamic range.

The fast photon counting and temperature control found in the TopCount NXT Scintillation Counter make it an ideal counter for luminescence analysis. The unique circuitry incorporated into this Packard model is capable of counting more photons per second than most dedicated microplate luminescence detection systems. Each counter is equipped with a small pmt with low inherent background. Typically difficult-to-measure applications such as small and low count rate samples receive high signal and low background with the help of specialized pipelines.

Users can insert the TopCount external stacker, which contains up to 40 microplates, for a fully automated counting process. Luminescence samples can produce more than 50,000 samples per day. Operators can also easily load new plates and unload counted Packard scintillation counters without interrupting the counting process.

Specification

Condition: certified pre-owned
Automatic Microplate Stacker: Accepts 20 and 40 plate stacker cassettes
Counting Technology: Patented TR-LSC Triple-Mode
Isothermal Counting Chamber: User selectable from 19 to 35’C
DPM Calculations: Both single and dual label DPM
Computer: IBM 350 MHz Pentium II
Operating System: Windows NT
Database: Hologram ODBC
Data Outputs: Raw counts, CPM, DPM, single and dual label, screening and elapsed time
Data Archiving: ASCII, Lotus or Excel
Printer Output: User selectable
Dimensions: 50.8 cm (H) x 94.0 cm (W) x 63.5 cm (D)
Weight: 91 kg without AES and cart; 127 kg with AES and without cart
Electrical Requirements: 117 Vac ± 10% 50/60 Hz 4.0 Amp protection; 220 Vac ± 15% 50/60 Hz 3.0 Amp protection; Power consumption 350 VA maximum, instrument only
Isothermal Cooling Electrical Requirements: 117 Vac ± 10% 50/60 Hz 8.0 Amp protection; 220 Vac ± 15% 50/60 Hz 5.0 Amp protection; Power consumption 940 VA maximum
Environmental Requirements: Operating ambient temperature 15 to 35 °C (59 to 90 °F); Operating relative humidity 30% to 85%

Features

Low flicker and glow background.
Efficient counting in opaque microplates.
Compatible with filter plates and pads.
Temperature-controlled counting chamber.
Choose from 2, 4, 6 or 12 detector models.

Related Products

Perkin Elmer 2450 Microbeta2, Solid Scintillator, Perkin Elmer (CAT#-STEM-AIAEPO-0207-LGZ)
Perkin Elmer Quantulus GCT Liquid Scintillation Counter, Energy Range 0–2,000 keV, Perkin Elmer (CAT#-STEM-AIAEPO-0208-LGZ)
Perkin Elmer Tri-Carb 4810TR Liquid Scintillation Counter, 100-240 Vac, Perkin Elmer (CAT#-STEM-AIAEPO-0209-LGZ)
Perkin Elmer Tri-Carb 4910TR Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#-STEM-AIAEPO-0210-LGZ)
Perkin Elmer Tri-Carb 5110TR Liquid Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#-STEM-AIAEPO-0211-LGZ)
Wallac 1450 MicroBeta TriLux Liquid Scintillation Counter & Lumi, Max. Sample Vial Diameter 13 mm, Wallac (CAT#-STEM-AIAEPO-0212-LGZ)
Advertisement