Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

QbD1200+ Laboratory TOC Analyzer, 0.4 - 100.000 ppb, Hach (CAT#: STEM-AI-0694-YJL)

Highlights

High repeatability
QbD1200+ TOC detector can reduce the interference between different sample measurements
The measurement results are consistent and repeatable

Cat Number: STEM-AI-0694-YJL

Application: It can be widely used in pharmaceutical, electric power, disease control, tap water and other industries. It can be used in QC laboratories of pharmaceutical companies, drug research and development, drug control institutes, power plants, CDC laboratories, third-party testing institutions, universities and research institutes, etc.

Model: QbD1200+

Add to Cart



Description

QbD1200+ Laboratory TOC Analyzer, 0.4 - 100.000 ppb, model QbD1200+ is manufactured by Hach. QbD1200+ is a laboratory TOC analyzer using UV lamp + persulfate oxidation method. The measuring range is between 0-100 ppm. It is suitable for industries with low sample concentrations such as pharmaceuticals, electric power, disease control, and tap water. The TOC analyzer has high repeatability, accurate measurement results, simple operation and easy maintenance, low cost of use, meets relevant pharmacopoeias and regulations, and can solve problems that have plagued customers for a long time. For example, when measuring low-concentration TOC, there will be problems such as poor repeatability, high cost of use, complicated maintenance and long calibration time, but these problems can be avoided by using the QbD1200+ laboratory TOC analyzer.

Specification

Performance
Measuring range: 0.4 ppb- 100.000 ppb
Measurement lower limit: 0.4ppb
Accuracy: <2% or 3ppb (whichever is greater)
Accuracy: ±2%
Calibration time: 90 minutes
Measurement time: <3% or 3 ppb (whichever is greater)
Drift between samples (from 500ppb → blank): < 0.2%
Over-range recovery (from 1000ppm→1ppm): 1 measurement can be recovered
Inorganic carbon treatment
Is an additional inorganic carbon removal module required when the concentration of inorganic carbon is high: No
Dynamic Endpoint Detection Guaranteed Complete Inorganic Carbon Removal: Yes
System self-diagnostics ensure data integrity
TOC measurement will stop under the following conditions: UV light intensity is too weak, carrier gas is insufficient/exhausted, reagent is insufficient/empty bottle, sample volume is insufficient/empty bottle
Reagent
Reagent source: Self-made or purchased from Hach
Types of reagents [acids, oxidizing agents, deionized water]: only one reagent for all measurements
Operation interface: display screen
10.4-inch high-resolution color touch screen
External computer: no external computer required
External keyboard/mouse: optional
Operability: Intuitive operation interface can guide users to measure
Measurement Methods and Guarantees
Oxidation method: UV lamp + persulfate
UV lamp: broadband silicon photodiode sensor
Detector: Digital NDIR
Detector stability: continuous confirmation with reference control
Detector moisture pre-cleaning: Peltier cooler. Continuous detection of flow
Dispenser Module: Syringe Pump, Accuracy +/-1%
Flow sensor: dynamic fluid sensor (to ensure accurate sample volume and reagent volume)
Type of carrier gas: (CO2-free) N, or O2
Carrier gas pressure measurement: dual hole pressure sensor
Carrier gas valve automatic closing function: when the measurement is completed, the valve will be closed to avoid wasting carrier gas
Auto-ranging function: Yes
Analysis Mode: NPOC (Non-Purgeable Organic Carbon)
Data storage and prosecution
Specification: 21 CFR part11. All measurements are recorded in encrypted database
Paperless report: FTP protocol Ethernet transmission
Output: 5 USB. One Ethernet port
Data output format: PDF, CSV
daily verification
Calibration: daily automatic calibration, 18-point calibration using KHP (6 concentrations, 3 replicate samples each)
Calibration solution: 5ppm KHP (125mL). Dilute to 1,2,3,4,5ppm concentration: reagent as blank
Validation Test/System Suitability USP System Suitability Bulk Water Set (Blank, 500ppb C-Sucrose, 500ppb C-Benzoquinone); USP System Suitability Sterile Water Set (Blank, 8ppm C-Sucrose.8ppm C-Benzoquinone); JP -16 <2.59> verification kit (blank 500ppb C-SDBS)
Compliance
Pharmacopoeia: USP<643> (including suitability test for sterile water system). JP-16 <2.59>. EP <2.2.44> , IP. CP. KP
US EPA: 5310c.415.3
21 CFR part 11: Compliance
ICH Guidelines for Instrument Validation including Accuracy, Precision, Limit of Detection LOD. Limit of Quantitation LOQ. Linearity, Range, Characterization, Stability: Compliance, included in I0/0Q
Autosampler
Maximum sample volume: 64 vials (standard 40mL glass TOC vials)
Style: XYZ triaxial. Diaphragm puncture
Sample tray material: anodized aluminum
General Technical Parameters
Instrument: Size: W320 * D507* H410 mm; Power: 100-240 VAC 47-63Hz; Weight: 10kg
Autosampler: Dimensions: W366*D537* H457 mm; Power: 100-240 VAC, 47-63H2z; Weight: 21kg
Operating environment: 10-35℃, maximum relative humidity 90% non-condensing
Measurement result unit: ug/L (ppb) or mg/L (ppm)

Features

High repeatability
QbD1200+ TOC detector can reduce the interference between different sample measurements
The measurement results are consistent and repeatable
Accurate measurement
QbD1200+ online TOC detector can support multiple different sensors for continuous monitoring
Both self-test and on-demand diagnostics are reported at startup
Over-range recovery function
Easy to operate and maintain
QbD1200+ TOC analyzer adopts 10.4-inch color touch screen, the user interface is more intuitive
Guided software interface, easy to operate the instrument
The QbD1200+ TOC analyzer comes with an automatic adjustment of the measurement range/dilution function, which can complete the measurement even if the sample concentration is not known in advance
Only one reagent is needed to complete the corresponding measurement and analysis (prepared by yourself or purchased from Hach)
QbD1200+ online TOC detector can support simple and convenient paperless function, and can export data to the network shared directory managed by windows security policy
Low cost of use
Low reagent cost
No need for frequent maintenance, just once a year
No need for a separate computer
Quick Calibration Saves Time
Calibration takes only 2 hours
The TOC meter has built-in automatic system suitability test for USP and EP and SDBS verification program for JP
Comply with pharmacopoeias and regulations
Comply with the regulations of major global pharmacopoeias, including: USP, JP, EP, IP, KP, ICH
Simplified IQ/OQ/PQ qualification procedures in compliance with ICH guidelines
Simple and automated process that can be applied in the following areas:
USP/EP SST bulk water
USP SST Sterile Water
JP SDBS verification
KHP calibration according to JP standard

Related Products

GANIMEDE Total Nitrogen Auto Analyzer,0.5-30 mg/L;30-150 mg/L (CAT#: STEM-AI-0691-YJL)
GANIMEDE Automatic Total Phosphorus Analyzer, 0.01-3.8 mg/L (CAT#: STEM-AI-0690-YJL)
QP1680 TOC (Total Organic Carbon) Analyzer, TOC (CAT#: STEM-AI-0698-YJL)
QP1680 TOC (Total Organic Carbon) Analyzer, TOC、TN (CAT#: STEM-AI-0699-YJL)
QP1680 TOC (Total Organic Carbon) Analyzer, TN (CAT#: STEM-AI-0700-YJL)
Advertisement