Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Real-Time Identification of Bacteria and Candida Species in Positive Blood Culture Broths by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (CAT#: STEM-ST-0329-LJX)

Introduction

Delays in the identification of microorganisms are a barrier to the establishment of adequate empirical antibiotic therapy of bacteremia. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) allows the identification of microorganisms directly from colonies within minutes. In this study, we have adapted and tested this technology for use with blood culture broths, thus allowing identification in less than 30 min once the blood culture is detected as positive. Our method is based on the selective recovery of bacteria by adding a detergent that solubilizes blood cells but not microbial membranes. Microorganisms are then extracted by centrifugation and analyzed by MALDI-TOF-MS. This strategy was first tested by inoculating various bacterial and fungal species into negative blood culture bottles. We then tested positive patient blood or fluid samples grown in blood culture bottles, and the results obtained by MALDI-TOF-MS were compared with those obtained using conventional strategies.




Principle

In a very small area and a very short time interval (ns order of magnitude), the laser delivers high-intensity pulse energy to the sample under test, causing it to desorption and ionize instantaneously without thermal decomposition. MALDI is a mass spectrometry ionization method for direct evaporation and ionization of non-volatile samples.

Applications

For measuring the molecular weight of biological macromolecules, such as the molecular weight distribution of peptides, proteins, nucleic acids, polymers and oligomer analysis.

Procedure

1. Mix the sample with the appropriate matrix material and load it onto the metal plate.
2. Pulsed laser light is used to irradiate the sample and trigger ablation and desorption of the sample and matrix materials.
3. Analyte molecules are ionized by protonation or deprotonation in the thermal plume of the ablated gas and are then accelerated to a mass analyzer for analysis.

Materials

• Sample Type:
Positive blood culture broths

Notes

1. During shutdown, if the nitrogen is not turned off, the pressure should be properly lowered to avoid moisture.
2. Keep an eye on instrument drift during manual measurement. If there is drift, the instrument needs to be calibrated with standard peptide or standard protein.
Advertisement