Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Roche Elecsys 2010 Rack Immunology Analyzer, 86 tests/hour, Roche (CAT#: STEM-CTEPO-0117-YJL)

Cat Number: STEM-CTEPO-0117-YJL

Application: For performing immunoassay tests.

Model: Elecsys 2010 Rack

Add to Cart



Description

Roche Elecsys 2010 Rack Immunology Analyzer, 86 tests/hour, model Elecsys 2010 Rack, is manufactured by Roche. The Roche Elecsys 2010 Rack version is a well respected Swiss designed and manufactured benchtop Immunoassay system. The robust and attractive analyzer boasts 48 assays and a throughput 86 tests per hour. Immunodiagnostic testing analyzes reactions between antigens and antibodies in response to infectious disease, autoimmune disorders, immune allergies and neoplastic disease. Antigens are foreign substances which enter a patient’s body and engage the immune system to respond. These substances most typically include toxins, tumors or microorganisms such as bacteria, virus, parasite or fungi. Antibodies are proteins produced by the body’s immune system in response to an antigen. The antigen-antibody response is the natural defense against invading organisms. Most immunochemistry systems use fluorescence as its operation principle. Fluorescence is the emission of electromagnetic radiation by a substance at one wavelength after it has absorbed energy at another wavelength. This reaction takes place in the Luminometer portion of the analyzer. The 2 main methods are referred to as Fluorescence Polarization Immunoassay (FPIA) and Chemiluminescence Immunoassay (CLIA). Nephelometry and Enzyme based immunoassay are less common methods used in immunochemistry analysis. Some of the enzyme methods are referred to as: Enzyme Immunoassay (EIA), Microparticle Enzyme Immunoassay (MEIA) and Enzyme –Linked Immunosorbent Assay (ELISA). Immunodiagnostic studies are divided into two primary categories. Analysis of infectious disease are referred to as serological testing while assessment of the patient’s immune system is referred to as immune dysfunctional analysis. Some immunology instrumentation may include testing of routine chemistries or therapeutic drugs for consolidated testing. Serologic tests are classified in 4 main groups as listed. The most common tests within these groups are listed: Bacterial Tests Syphilis, Lyme, Legionnaire, Chlamydia, Streptococcal Viral Tests Mononucleosis, Epstein Barr, Rubella, Hepatitis, Rabies, HIV, Aids, Herpes Fungal Tests Histoplasmosis, Blastomycosis, Candida, Aspergillus, Cryptococcus Parasitic Tests Toxoplasmosis, Amebiasis Tests for Immune Dysfunction are used to diagnose inflammatory states, neoplastic states, nephtoric syndromes, liver disease and immune dysfunctions leading to typically, cancer. The most common tests for dysfunction are: Quantitative Immunoglobulins (IgA, IgG, IgM) Cryoglobulin Tests Collagen, Rheumatic and Connective Tissue Disease Tests Complement Components (C3,C4,C1) Antinuclear Antibody (ANA) Antiscleroderma (SCl-70) Antibody Test Total Hemolytic Complement (CH50) Anti-Smooth Muscle Antibody (ASMA) Test Antimitochondrial Antibody (AMA) Test Antiparietal Cell Antibody (APCA) Test IgE Antibody Cardiolipin Antibodies Cytoplasmic Neutrophil Antibodies (ANCA) Antisperm Antibody Test Alzheimers Disease Markers Tumor Markers

Specification

Condition: Certified Pre-Owned
Auto Sample Handling: No
CLIA Complexity: Moderate
Configuration: Bench Top
Depth: 95 cm (37 in)
Direct Sample (STAT): Yes
Height: 56 cm (22 in)
Manufacturer: Roche Diagnostics
Maximum Throughput: 86 tests/hour
Number of Assays: 47
On-Board Refrigeration: No
Patient Sample Capacity: 75
Point Of Care: No
Power Supply: 110V-220V
Reagent Capacity: 18
Reagent System: Closed
Reagent Type: Liquid
Sample Cycle Time: 42 (sec)
Sample Input Closed Tube: No
Sample Input Type:
Sample Tubes
Sample Cups
Sample Size Max: 50 μL
Sample Size Min: 10 μL
Sample Types: Plasma, Serum
Series: Elecsys
Standby Mode: Yes
Test Method:
Electro Chemiluminescence (ECLIA)
Weight: 210 kg (462 lb)
Width: 170 cm (67 in)

Related Products

Ortho Clinical Diagnostics VITROS ECiQ Immunodiagnostic System, 100 BTUs/hour, Ortho Clinical (CAT#: STEM-CTEPO-0109-YJL)
Ortho Clinical Vitros 3600 Immunodiagnostic System, 10-80 μL, Ortho Clinical (CAT#: STEM-CTEPO-0110-YJL)
Roche Cobas 6000 Core Immunology Analyzer, 600 tests/hour, Roche (CAT#: STEM-CTEPO-0111-YJL)
Roche Cobas E411 Disk Immunology Analyzer, 86 tests/hour, Roche (CAT#: STEM-CTEPO-0112-YJL)
Roche Cobas E411 Rack Immunology Analyzer, 86 tests/hour, Roche (CAT#: STEM-CTEPO-0113-YJL)
Advertisement