Full computer touch screen microprocessing system, color touch screen control display mode, the operation panel can be moved freely, you can add fermentation unit. It can monitor stirring (100-1500rpm), temperature (0-100℃), pH (2-14), PO2 (0-100%), mass flow rate, defoaming, feeding, gas mixing and other parameters.
More extended control: can be increased to 24 parameters, turbidity, biomass, exit gas analysis, (CO2 /O2), mass (connected balance), pressure, glucose, methanol, etc.
Tank size selection: 2.0L/1.0L; 3.6L/2.5L; 7.5L/5.0L; 10L/7.5L; 13L/10L.
Heating jacket temperature control or glass jacket temperature control, temperature range: glass jacket temperature control: cooling medium temperature +5℃~70℃; Accuracy 0.1℃; Heating sleeve temperature control: cooling medium temperature +5℃~95℃; Accuracy 0.1℃.
Off-position sterilization method, easy disassembly and installation, reduce the probability of contamination.
The pO2 menu can be controlled with each parameter, the user can customize the cascade parameters and cascade priority according to the experimental conditions, and can set the horizontal cascade or vertical cascade JQ control pO2
The microbial culture was performed by mechanical stirring, the rotational speed was 10~1500rpm, and the dissolved stirring paddle was used for bacterial fermentation
Memory card can quickly record setting parameters and graphics, which is convenient for users to directly call the next experiment and ensure the safe interpretation of key experimental data
The control system of Labfors5 can control up to six Labfors5 master control units simultaneously
4 high-precision automatic peristaltic pumps, can also be manually controlled, easy disassembly, installation, can complete high temperature autoclave sterilization, more saving operation time.
Intake mode:
Rotameter control gas flow, you can choose the mass flow meter to accurately measure and control the intake volume, you can choose a single gas (Air) or gas mixing station (Air+O2+other gas), inlet and outlet filter for 0.2um membrane filter.
Aseptic sampling system, can be high temperature autoclave sterilization, and a check valve design, get rid of the sampling process easy to contaminate bacteria distress.
INFORS 'Iris control software records the biological reaction process in real time, supports online monitoring and remote monitoring of parameters, and has real-time curves. In addition to basic process monitoring means, IRIS software can also be programmed to control, and can feedback and control another parameter through changes in one parameter, alarm information, inoculation time and other conditions. It also has the tracking fermentation function, which can repeat the process of a previous fermentation to better complete the purpose of repeated fermentation. It can be used in combination with the tail gas analyzer to display the fermentation process parameters such as CER\OUR\RQ\KLA in real time by adding calculation parameters.
Highly integrated system, ultra-small space utilization. Standard specifications: Occupied area: 422 x 424 mm; Contains the dimensions of the basic gas supply system and corresponding piping