Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Siemens Advia 1800 Chemistry Analyzer, Ambient Humidity 40%-70%, Siemens (CAT#: STEM-AIAEPO-0092-LGZ)

Cat Number: STEM-AIAEPO-0092-LGZ

Application: For chemical analysis.

Model: Advia 1800

Add to Cart



Description

The ADVIA® 1800 Clinical Chemistry System pushes the limits of productivity. Its extensive menu allows for integrated testing of clinical chemistry, drugs of abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and cardiphase® hsCRP. The ADVIA 1800 Clinical Chemistry System provides:

Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks.
200 basic metabolic plates per hour to meet turnaround time demands.
Large onboard reagent capacity and optional concentrate reagents reduce disruption.
Optimum standardization of reagents and systems for efficient use of consumables.
Onboard refrigerated storage of controls and reagents for extended stability and increased productivity.
Automated design - no additional hardware required.

Specification

Condition: certified pre-owned
Overview

Type of System: Random, continuous access, batch, discrete processing
Throughput Rate: Up to 1800 tests/hour: 1200 tests/hour colorimetric, 600 tests/hour ISE
Assay Capacity Onboard: 55 including 3 ISE

Sample Handling

Sample Tubes: 5 mL, 7 mL, 10 mL tubes, 2 mL sample cups
Sample Tray: 84 samples, positive sample identification
Sample Integrity Check: Qualitative check for hemolysis, lipemia, and icterus
STAT Sample Loading: 84, not dedicated
Bar Codes: Interleaved 2 of 5, Code 39, Code 128, Codabar (NW7)
Auto-repeat: Automatic repeat testing from the retained prediluted sample or original sample
Auto-dilution: Automatic dilution from retained prediluted sample
Auto-reflex Testing: Automatic ability to perform 3 additional tests based on results of first test
Primary Probe: Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection

Microvolume Technology

Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 tests), retained for auto-repeat until results are available
Predilution Tray: 120 dilution cuvettes
Original Sample Volume: 2 to 30 μL; average of 2-3 μL per test
Average Reagent Volume: 80-120 μL per test
Storage Capacity Onboard: 25,200 tests average; Usage of concentrated reagents increases maximum capacity

Reaction Area

Reaction Tray: 221 reusable plastic cuvettes
Cuvette Optical Path Length: 10 mm
Reaction Bath: Inert fluorocarbon oil circulation system, 37°C
Photometer: 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm)
Light Source: 12 V, 50 W halogen lamp, cooled by forced water circulation
Assay Methods: Endpoint, rate reaction, 2-point rate, multipoint homogeneous immunoassay
Reaction Times: 3, 4, 5, 10, 15, and 21 minutes
Automatic Correction: Serum blank, cell blank, measurement point change, sample volume change in reassay
Point Forwarding: Automatically extends linearity over assay range samples

Reagent Handling

Reagent Tray: 2 trays, 56 positions each, refrigerated
Reagent Capacity Onboard: 52 colorimetric methods
Dispensing System: 2 probes with Liquid Level Sensing and Liquid Surface Verification
Reagent Wedges: 20, 40, 70 mL bar-code-labeled wedges
Reagent Inventory Management: Tracks tests remaining, lot number, onboard stability, and expiration date
Reagent Dilutions: Capability to dilute concentrated reagents onboard
Onboard Stability: Up to 60 days

Open System Capability

Channels: 200 channels, includes user-defined applications
3rd Party Applications: Varies by country, can be configured on system

ISE

ISE: Indirect simultaneous measurement of Na+, K+, Cl –
Sample Volume: 22 μL for all three tests
Priming: Automatic priming cycle
Electrode Shelf Life: 30,000 samples or 3 months
Throughput Rate: 600 tests/hour; 200 tubes/hour

Calibration/QC

Calibration Interval: Up to 60 days, tracked by software
Auto-calibration/Auto-QC: User-defined time interval or with new reagent container
View Calibration/QC Data: Graphical display of calibration curves and QC; Siemens Remote Service QC monitoring
Calibration/Control Tray: 61 refrigerated positions for calibrators, controls, and diluents

Data Management

Operating Computer: Windows® XP, 1 GB RAM, touch screen monitor 19”
System Documentation: Operator manual and assay sheets online
Host Interface: RS 232C bidirectional
Data Storage: 70,000 patient tests
Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via software
Host Query: ASCII; system requests work order or batch of work orders from host

General Specifications

Power Requirements: 200/220/230/240 V +/– 10%, 20 A, 50/60 Hz, 3 KVA
Water Requirements: Deionized water from pressurized water (10-30 psi/169-207 KPa) Average Consumption: 30 liters per hour
Drain Requirements: Minimum of 40 liters per hour
Dimensions: ADVIA 1800: 44.6 (h) x 58.3 (w) x 34.5 (d) in, 113.3 (h) x 148.0 (w) x 87.6 (d) cm
Weight: ADVIA 1800: 1,323 lbs (600 kg)
Compliance: UL, cUL, CE
Noise Specifications: Open cover less than 70 db
Average Heat Output: 4,299 BTU/hour @ 50 Hz, 3,023 BTU/hour @ 60 Hz
Operating Temperature Range: 18°-30°C/64°-86°F
Ambient Humidity: 40%-70%

Related Products

Beckman Coulter AU640e Chemistry Analyzer, Weight 530 kg, Beckman Coulter (CAT#-STEM-AIAEPO-0036-LGZ)
Beckman Coulter AU680 Chemistry Analyzer, Total Reaction Volume 120–425 μL, Beckman Coulter (CAT#-STEM-AIAEPO-0037-LGZ)
Beckman Coulter AU680 wISE Chemistry Analyzer, Reaction Temperature 37°C, Beckman Coulter (CAT#-STEM-AIAEPO-0038-LGZ)
Beckman Coulter UniCel DxC 600 Chemistry Analyzer, 110V-220V, Beckman Coulter (CAT#-STEM-AIAEPO-0039-LGZ)
Beckman Coulter UniCel DxC 600 Pro Chemistry Analyzer, Sample Size Max 40 μL, Beckman Coulter (CAT#-STEM-AIAEPO-0040-LGZ)
Beckman Coulter UniCel DxC 800 Chemistry Analyzer, Beckman Coulter (CAT#-STEM-AIAEPO-0041-LGZ)
Advertisement