Condition: certified pre-owned
Overview
Type of System: Random, continuous access, batch, discrete processing
Throughput Rate: Up to 1800 tests/hour: 1200 tests/hour colorimetric, 600 tests/hour ISE
Assay Capacity Onboard: 55 including 3 ISE
Sample Handling
Sample Tubes: 5 mL, 7 mL, 10 mL tubes, 2 mL sample cups
Sample Tray: 84 samples, positive sample identification
Sample Integrity Check: Qualitative check for hemolysis, lipemia, and icterus
STAT Sample Loading: 84, not dedicated
Bar Codes: Interleaved 2 of 5, Code 39, Code 128, Codabar (NW7)
Auto-repeat: Automatic repeat testing from the retained prediluted sample or original sample
Auto-dilution: Automatic dilution from retained prediluted sample
Auto-reflex Testing: Automatic ability to perform 3 additional tests based on results of first test
Primary Probe: Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection
Microvolume Technology
Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 tests), retained for auto-repeat until results are available
Predilution Tray: 120 dilution cuvettes
Original Sample Volume: 2 to 30 μL; average of 2-3 μL per test
Average Reagent Volume: 80-120 μL per test
Storage Capacity Onboard: 25,200 tests average; Usage of concentrated reagents increases maximum capacity
Reaction Area
Reaction Tray: 221 reusable plastic cuvettes
Cuvette Optical Path Length: 10 mm
Reaction Bath: Inert fluorocarbon oil circulation system, 37°C
Photometer: 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm)
Light Source: 12 V, 50 W halogen lamp, cooled by forced water circulation
Assay Methods: Endpoint, rate reaction, 2-point rate, multipoint homogeneous immunoassay
Reaction Times: 3, 4, 5, 10, 15, and 21 minutes
Automatic Correction: Serum blank, cell blank, measurement point change, sample volume change in reassay
Point Forwarding: Automatically extends linearity over assay range samples
Reagent Handling
Reagent Tray: 2 trays, 56 positions each, refrigerated
Reagent Capacity Onboard: 52 colorimetric methods
Dispensing System: 2 probes with Liquid Level Sensing and Liquid Surface Verification
Reagent Wedges: 20, 40, 70 mL bar-code-labeled wedges
Reagent Inventory Management: Tracks tests remaining, lot number, onboard stability, and expiration date
Reagent Dilutions: Capability to dilute concentrated reagents onboard
Onboard Stability: Up to 60 days
Open System Capability
Channels: 200 channels, includes user-defined applications
3rd Party Applications: Varies by country, can be configured on system
ISE
ISE: Indirect simultaneous measurement of Na+, K+, Cl –
Sample Volume: 22 μL for all three tests
Priming: Automatic priming cycle
Electrode Shelf Life: 30,000 samples or 3 months
Throughput Rate: 600 tests/hour; 200 tubes/hour
Calibration/QC
Calibration Interval: Up to 60 days, tracked by software
Auto-calibration/Auto-QC: User-defined time interval or with new reagent container
View Calibration/QC Data: Graphical display of calibration curves and QC; Siemens Remote Service QC monitoring
Calibration/Control Tray: 61 refrigerated positions for calibrators, controls, and diluents
Data Management
Operating Computer: Windows® XP, 1 GB RAM, touch screen monitor 19”
System Documentation: Operator manual and assay sheets online
Host Interface: RS 232C bidirectional
Data Storage: 70,000 patient tests
Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via software
Host Query: ASCII; system requests work order or batch of work orders from host
General Specifications
Power Requirements: 200/220/230/240 V +/– 10%, 20 A, 50/60 Hz, 3 KVA
Water Requirements: Deionized water from pressurized water (10-30 psi/169-207 KPa) Average Consumption: 30 liters per hour
Drain Requirements: Minimum of 40 liters per hour
Dimensions: ADVIA 1800: 44.6 (h) x 58.3 (w) x 34.5 (d) in, 113.3 (h) x 148.0 (w) x 87.6 (d) cm
Weight: ADVIA 1800: 1,323 lbs (600 kg)
Compliance: UL, cUL, CE
Noise Specifications: Open cover less than 70 db
Average Heat Output: 4,299 BTU/hour @ 50 Hz, 3,023 BTU/hour @ 60 Hz
Operating Temperature Range: 18°-30°C/64°-86°F
Ambient Humidity: 40%-70%