The Siemens/Bayer DCA 2000+ analyzer is a point-of-care management platform for diabetes. This hematology analyzer can efficiently perform HbA1c and microalbumin/creatinine tests in minutes. At the same time, the analyzer allows healthcare professionals to make immediate diabetes management adjustments. The DCA 2000+ Analyzer system can also measure low concentrations of albumin, creatinine and the albumin/creatinine ratio in urine. This method can use random urine samples for decentralized testing, which can lead to early detection of problems associated with kidney disease.
Because of its completely self-contained kit, the Bayer DCA 2000+ glycohemoglobin analyzer requires no reagent preparation, mixing, or handling. The sample collection capillary holder is the core part of the dedicated kit. This factory calibrated analyzer also eliminates all wet, expensive and time-consuming calibrations.
The Siemens DCA 2000+ analyzer guarantees laboratory-accurate results, including HBA1c and microalbumin/creatinine ratio results, within minutes of testing. Using random urine samples, the Siemens Bayer Hematology Analyzer calculates and displays quantitative results within 7 minutes. Up to 16 results can be stored in memory, making record keeping very convenient. Additional features include an on-screen display of all commands, calibration status, test information and results.
Specification
Condition: certified pre-owned Dimensions (HxWxD): 23.9 x 24.1 x 27.2 (cm); 9.4 x 9.5 x 10.7 (in) Weight: 11.0 lb (5.0 kg) Power: 100V to 240V (O.4A) 50/60 Hz Ambient Operating Temperature Range: 15 to 32 deg C (59 to 90 deg F) Ambient Operating Humidity Range: 10% to 90% (non-condensing) Hemoglobin A1c (HBA1c): Yes Reagent Supply (Detection): Yes Testing Technique (Detection): Latex immunoagglutination inhibition methodology (HbA1c), immunoturbidimetric, agglutination complex (microalbumin), Benedict/Behre chemistry (creatinine) Attributes: Individually foil-wrapped reagent cartridges; memory stores 16 test results, 16 control results; factory bar code calibration; microalbumin/creatinine, microalbumin, creatinine with ratio; 4 reagent calibrations (2 HBA1c and 2 Malib/Creat) Configuration: Benchtop Computer Interface: RS232 Refrigerated (Tests): Reagents stable for 3 months at room temperature Printer (External Beam): Equipped with Centronics/parallel port Sample Required: Whole blood, finger prick or venipuncture Sample Volume (µl): 1 Performance Time: 6 min. CE Mark (MDD) (Interference Compensation): Yes