Starrsed Interliner ESR Analyzer Unit, RR Mechatronics (CAT#: STEM-CTEPO-0012-ZJF)

Highlights

As the Westergren glass tubes are re-usable after each automatic cleaning with Starrsed cleaning-agent, there is no additional costs for new pipettes. No disposable plastics of any kind are used.
It is easy to add the Starrsed RS to your laboratory as it accepts virtually every brand of blood cell counter rack and all regular types of sample tubes.
As opposed to other ESR test instruments, Starrsed instruments actually identify and report hazy samples so that the lab technician may decide on further testing.

Cat Number: STEM-CTEPO-0012-ZJF

Application: For ESR analysis.

Model: ESRI109003

Add to Cart



Description

The Starrsed Interliner ESR Analyzer Unit is manufactured by RR Mechatronics.
The Starrsed Interliner makes continuous production of the ESR analyses available, as a segment within a complete production line or as a stand-alone instrument. Easy loading of the samples from the racks into the instrument. Fully automatic barcode reading for an optimum co-operation with the administration- and report software. Fully automated preparation of samples before aspiration.
The pre-owned products will be thoroughly cleaned and fully tested to perform at manufacturer specifications before shipping.

Specification

Condition: Certified Pre-Owned
Electrical: 115VAC, 50/60Hz, 500VA

Features

As the Westergren glass tubes are re-usable after each automatic cleaning with Starrsed cleaning-agent, there is no additional costs for new pipettes. No disposable plastics of any kind are used.
It is easy to add the Starrsed RS to your laboratory as it accepts virtually every brand of blood cell counter rack and all regular types of sample tubes.
As opposed to other ESR test instruments, Starrsed instruments actually identify and report hazy samples so that the lab technician may decide on further testing.
The Starrsed RS makes use of EDTA sample tubes. The advantage is that EDTA blood is very stable compared to pre-citrated samples, allowing for accurate ESR test results up to 24 hours after collection. This provides laboratories with even more logistical flexibility.
Because the Starrsed RS dilutes the blood, which is in agreement with the Westergren Method, it compensates for different hematocrit levels. The hematocrit level of the sample therefore will not influence the accuracy of the ESR measured.