Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Thermo Scientific NanoDrop 1000, 220 - 750 nm, Thermo Scientific (CAT#: STEM-SPO-0043-YJL)

Cat Number: STEM-SPO-0043-YJL

Application: For measuring: nucleic acid concentration and purity of nucleic acid samples

Model: NanoDrop 1000

Add to Cart



Description

Thermo Scientific NanoDrop 1000, 220 - 750 nm, model NanoDrop 1000, is manufactured by Thermo Scientific. The NanoDrop ND-1000 is a full-spectrum spectrophotometer that measures 1 ul samples with high accuracy and reproducibility. The system uses 1mm and 0.2mm path lengths for each measurement cycle to provide an extensive dynamic range. The ND-1000 can measure high-concentration samples without dilution that many standard cuvette spectrophotometers cannot, measuring up to 50 times more concentrated solutions. Surface tension technology keeps the sample in place without the need for sample containment devices and allows for quick cleanup. Applications include measuring: nucleic acid concentration and purity of nucleic acid samples up to 3700 nh/ul without dilution; fluorescent dye labeling density of nucleic acid microarray samples; purified protein analysis up to 100 mg/ml; expanded spectrum measurement and quantitation of fluorescent dye labeled proteins, conjugates, and metalloproteins; Bradford Assay analysis of protein; BCA Assay analysis of protein; Lowry Assay analysis of protein; cell density measurements; and general UV-Vis spectrophotometry.
All of our equipment is fully tested to perform at factory specifications before being shipped.

Specification

Condition: Certified Pre-Owned
Sample Size: 1 microliter
Path Length: 1mm (with auto-ranging to 0.2 mm)
Light Source: Xenon flash lamp
Detector Type: 2048-element linear silicon CCD array
Wavelength Range: 220 to 750 nm
Wavelength Accuracy: 1 nm
Wavelength Resolution: 3 nm (FWHM at Hg 546 nm)
Absorbance Precision: 0.003 absorbance (1mm path)
Absorbance Range: 0.02 to 75 (10 mm equivalent absorbance)
Detection Limit: 2 ng/microliter (dsDNA)
Maximum Concentration: 3700 ng/microliter (dsDNA)
Measurement Cycle Time: 10 seconds
Dimensions: 14 x 20 cm

Related Products

Beckman DU 530 UV Vis Spectrophotometer, Beckman Coulter (CAT#: STEM-SPO-0045-YJL)
Beckman DU 7400 Diode Array Spectrophotometer, 190 – 800 nm, Beckman Coulter (CAT#: STEM-SPO-0046-YJL)
Beckman DU-640 Spectrophotometer, Beckman Coulter (CAT#: STEM-SPO-0047-YJL)
Thermo Scientific NanoDrop Series Spectrophotometers, 260 and 280 nm, Thermo Scientific (CAT#: STEM-SPO-0048-YJL)
Thermo Scientific NanoDrop Series Spectrophotometers, 190 – 840 nm, Thermo Scientific (CAT#: STEM-SPO-0049-YJL)
Thermo Scientifics NanoDrop 2000c Spectrophometer, 190 – 840 nm, Thermo Scientific (CAT#: STEM-SPO-0050-YJL)
Advertisement