Condition: Used
Electrical: 100-240V, 50/60H, 1.2Amps
Input Types: 8 Inputs; Active 24VDC switch selectable as NPN or PNP
Flange Option: Standard 50 mm flanges to reduce the metal free zone
Languages: English, Chinese, Dutch, French, German, Italian, Portuguese, Russian, Spanish, Czech
Aperture Size: Width: 100 to 450 mm, Height: 75 to 250 mm
Not all combinations are possible; contact Thermo Fisher Scientific for details.
Sensitivity: Detects contaminants up to 15% smaller in diameter than the Thermo Scientific APEX 300 metal detector (subject to application testing)
Communications:
7 in (178 mm) diagonal, high-intensity color touchscreen
Watertight USB 2.0
Construction : Stainless steel 304 straightline finished case and front panel
Electronic Supply: 100 volts to 240 volts AC single phase plus earth ground; 50 Hz to 60 Hz, 0.6 to 1.2 amps
Manufacturing Quality: ISO9001 certified
Operating Temperature:
Metal Detector Ambient Temperature -10° to +40°C (+14° to +104°F)
Product Temperature in Aperture -10° to +55°C (+14° to +131°F)
Maximum Washdown Temperature 55°C (131°F)
Output Types:
8 relay outputs; 250 volt AC 2 amp max. 50 volt DC 1 amp max
8 digital sourcing (PNP) outputs, 24VDC with capacity of any two at 500 mA, the rest at 30 mA average each
Product Speed: 0.5 m/min (1.7 ft/min) to 80 m/min (262 ft/min)
Relative Humidity: 20% to 80% non-condensing, one way breather valve standard
Input Allocation: Speed Sensor, Infeed Photo Eye, Reject Confirmation 1 and Bin Full, External Alarm, External Reset
Output Allocation: Reject 1, Reject 2, Fault, Alarm, Warning