Thyreostatic Drug Detection in Animal Tissues by High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry (CAT#: STEM-ST-0093-LJX)

Introduction

Thyreostatic drugs (thyreostats) interfere with thyroid function and have been used illegally in animals slaughtered for food. Thyreostat use leads to poorer quality meat, and the drug residues can cause adverse effects in humans. These drugs, with the exception of thiouracil, do not occur naturally and require sensitive methodologies for their detection in animal tissues. Because thyreostats are low-molecular-weight polar analytes, liquid chromatography-mass spectrometry (LC-MS) is typically used for detection and, in particular, triple quadrupole mass spectrometry with selective reaction monitoring (i.e., LC-SRM). However, LC-SRM thyreostat methods suffer from chemical background noise and endogenous interferences arising from the complex tissue matrix. An improved high-field asymmetric waveform ion mobility spectrometry interface (FAIMS Pro), which separates ions based on differential ion mobility, was combined with LC-SRM to minimize these interferences.




Principle

Ion mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.

Applications

For studying the gas phase ion structure
For detecting the chemical warfare agents and explosives
For the analysis of proteins, peptides, drug-like molecules and nano particles
For monitoring isomeric reaction intermediates and probe their kinetics
For proteomics and pharmaceutical analysis

Procedure

1. Add sample
2. The ions in the sample are separated in the ion mobility spectrometer
3. The separated ions are introduced into the mass analyzer for detection
4. Store the detection results

Materials

• Sample Type:
Thyreostatic drug

Notes

1. Ion mobility spectrometry is also a very fast technique, making it suitable for high-throughput applications. The entire analysis can be completed in just a few minutes.
2. The method is extremely sensitive and able to detect trace amounts of contaminants that other spectrometry methods would miss.
3. The effective separation of analytes achieved with this method makes it widely applicable in the analysis of complex samples such as in proteomics and metabolomics.