Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Bio-Rad 1651745 Vapor Vacuum Trap Electrophoresis Gel Dry In Jessup, MD, USA (CAT#: STEM-EPO-0024-YJL)

Cat Number: STEM-EPO-0024-YJL

Application: For gel drying

Model: 1651745

Add to Cart



Description

Bio-Rad 1651745 Vapor Vacuum Trap Electrophoresis Gel Dry In Jessup, MD, USA, model 1651745, is manufactured by Bio-Rad general medical equipment.
The Bio-Rad Vapor Trap Model 165-1745 features a trapping capacity of approximately 500ml and a condensed vapor capacity of 1.5 liters.

Specification

Condition: Used
Electrical: 120V, 60Hz, 300W, 3 Amp
Power Module
Dimensions (W x D x H): 55.9 x 34.5 x 30 cm
Construction: Aluminum chassis
Weight: 16 kg (35.3 lb)
Power supply: 350 V maximum, to allow maximum gradient of 9 V/cm, continuously adjustable; built in
Maximum current: 0.5 A
Allowable voltage gradients: 0.6–9 V/cm, in 0.1 V/cm increments
Battery back-up: All parameters in memory, up to 3 hr of interruption
Delayed start: Up to 72 hr
Electrode potentials: Dynamically regulated (feedback adjustment) +/- 0.5% F.S.
Program storage: 20 average size protocols
Display: Fluorescent, 2 lines x 40 characters per line, alphanumeric
Environmental
Operating temperature: 50°F (10°C) to 90°F (32°C); 30–80% humidity
Storage temperature: 32°F (0°C) to 140°F (60°C); 10–90% humidity
Switching Functions
Switching range: 50 ms to 18 hr
Switch angle variable: 0–360° (all electronic switching) in 0.5° increments
Multistate vector switching: Up to 15 vectors per pulse cycle, each definable by angle, voltage, and duration
Switch time ramps: Linear, concave, or convex using hyperbolic function
Secondary pulses: Defined by voltage, frequency, angle, and duration
Field inversion (FIGE): Available with asymmetric forward, reverse voltages
Maximum program blocks: 8, with automatic execution
Maximum run time: 999 hr per block
Fuses: 3 A Slow-Blow; two each for AC line input
Electrophoresis Cell
Dimensions (W x D x H): 44.2 x 50.3 x 11.4 cm, horizontal format
Construction: Cover: vacuum-formed polycarbonate, base: injection-molded polycarbonate
Lid: Safety interlocked
Weight: 10.2 kg (22.5 lb)
Electrodes: 24, platinum (0.02" diameter)
Temperature monitoring: Via precision temperature probe mounted in base of cell

Related Products

Bio-Rad Model 583, 50–90°C In New Jersey, USA (CAT#: STEM-EPO-0010-YJL)
Bio-Rad GelAir Dryer In Woonsocket, RI, USA (CAT#: STEM-EPO-0031-YJL)
Bio-Rad Gel Air In Woonsocket, RI, USA (CAT#: STEM-EPO-0032-YJL)
Biorad 583 In Farmingdale, NJ, USA (CAT#: STEM-EPO-0046-YJL)

Other recommended products

Advertisement