Bio-Rad Cooling Module In Woonsocket, RI, USA (CAT#: STEM-EPO-0025-YJL)

Cat Number: STEM-EPO-0025-YJL

Application: For cooling

Model: Bio-Rad MODULE

Add to Cart



Description

Bio-Rad Cooling Module In Woonsocket, RI, USA, model Bio-Rad MODULE, is manufactured by Bio-Rad general laboratory equipment.
Used Bio-Rad Cooling Module for sale.
Bio-Rad Cooling Module Electrophoresis buffer is circulated from the electrophoresis chamber by the variable speed bump, cooled directly by the liquid refrigerant in a heat exchanger within the Cooling Module, and returned to the electrophoresis chamber. The heat exchanger is electrically isolated from the chassis, compressor, and plumbing to eliminate electrical shock hazard. The Cooling Module maintains a constant buffer temperature typically within 1 C of the set temperature in an operating range of 5-25 C for a total buffer capacity of 2.2 liters at a flow rate of 1.0 liter/minute. Maximum buffer cooling capacity is 75 watts of input power at a set temperature of 14 C.

Specification

Condition: Used
Pressure limits: 3-20 in Hg
Power Module
Dimensions (W x D x H): 55.9 x 34.5 x 30 cm
Construction: Aluminum chassis
Weight: 16 kg (35.3 lb)
Power supply: 350 V maximum, to allow maximum gradient of 9 V/cm, continuously adjustable; built in
Maximum current: 0.5 A
Allowable voltage gradients: 0.6–9 V/cm, in 0.1 V/cm increments
Battery back-up: All parameters in memory, up to 3 hr of interruption
Delayed start: Up to 72 hr
Electrode potentials: Dynamically regulated (feedback adjustment) +/- 0.5% F.S.
Program storage: 20 average size protocols
Display: Fluorescent, 2 lines x 40 characters per line, alphanumeric
Environmental
Operating temperature: 50°F (10°C) to 90°F (32°C); 30–80% humidity
Storage temperature: 32°F (0°C) to 140°F (60°C); 10–90% humidity
Switching Functions
Switching range: 50 ms to 18 hr
Switch angle variable: 0–360° (all electronic switching) in 0.5° increments
Multistate vector switching: Up to 15 vectors per pulse cycle, each definable by angle, voltage, and duration
Switch time ramps: Linear, concave, or convex using hyperbolic function
Secondary pulses: Defined by voltage, frequency, angle, and duration
Field inversion (FIGE): Available with asymmetric forward, reverse voltages
Maximum program blocks: 8, with automatic execution
Maximum run time: 999 hr per block
Fuses: 3 A Slow-Blow; two each for AC line input
Electrophoresis Cell
Dimensions (W x D x H): 44.2 x 50.3 x 11.4 cm, horizontal format
Construction: Cover: vacuum-formed polycarbonate, base: injection-molded polycarbonate
Lid: Safety interlocked
Weight: 10.2 kg (22.5 lb)
Electrodes: 24, platinum (0.02" diameter)
Temperature monitoring: Via precision temperature probe mounted in base of cell

Related Products

Bio-Rad, 0.1 to 65,000 sec In Elkin, NC, USA (CAT#: STEM-EPO-0009-YJL)
BioRad Bio-Rad Vapor Trap, 1.5 liters 30 Day warranty! In Tucker, GA, USA (CAT#: STEM-EPO-0013-YJL)
Bio-Rad Electrophoresis Cell Laboratory In Elkin, NC, USA (CAT#: STEM-EPO-0015-YJL)
Bio-Rad 1703649 Electrophoresis Cell Laboratory In Elkin, NC, USA (CAT#: STEM-EPO-0016-YJL)
Bio-Rad Cooling Module (Non-CFC) In Elkin, NC, USA (CAT#: STEM-EPO-0017-YJL)
Bio-Rad CHEF-DR ll Drive Module, 43 x 26 x 14 cm In Elkin, NC, USA (CAT#: STEM-EPO-0018-YJL)
Advertisement