Bio-Rad Cooling Module In Woonsocket, RI, USA, model Bio-Rad MODULE, is manufactured by Bio-Rad general laboratory equipment. Used Bio-Rad Cooling Module for sale. Bio-Rad Cooling Module Electrophoresis buffer is circulated from the electrophoresis chamber by the variable speed bump, cooled directly by the liquid refrigerant in a heat exchanger within the Cooling Module, and returned to the electrophoresis chamber. The heat exchanger is electrically isolated from the chassis, compressor, and plumbing to eliminate electrical shock hazard. The Cooling Module maintains a constant buffer temperature typically within 1 C of the set temperature in an operating range of 5-25 C for a total buffer capacity of 2.2 liters at a flow rate of 1.0 liter/minute. Maximum buffer cooling capacity is 75 watts of input power at a set temperature of 14 C.
Specification
Condition: Used Pressure limits: 3-20 in Hg Power Module Dimensions (W x D x H): 55.9 x 34.5 x 30 cm Construction: Aluminum chassis Weight: 16 kg (35.3 lb) Power supply: 350 V maximum, to allow maximum gradient of 9 V/cm, continuously adjustable; built in Maximum current: 0.5 A Allowable voltage gradients: 0.6–9 V/cm, in 0.1 V/cm increments Battery back-up: All parameters in memory, up to 3 hr of interruption Delayed start: Up to 72 hr Electrode potentials: Dynamically regulated (feedback adjustment) +/- 0.5% F.S. Program storage: 20 average size protocols Display: Fluorescent, 2 lines x 40 characters per line, alphanumeric Environmental Operating temperature: 50°F (10°C) to 90°F (32°C); 30–80% humidity Storage temperature: 32°F (0°C) to 140°F (60°C); 10–90% humidity Switching Functions Switching range: 50 ms to 18 hr Switch angle variable: 0–360° (all electronic switching) in 0.5° increments Multistate vector switching: Up to 15 vectors per pulse cycle, each definable by angle, voltage, and duration Switch time ramps: Linear, concave, or convex using hyperbolic function Secondary pulses: Defined by voltage, frequency, angle, and duration Field inversion (FIGE): Available with asymmetric forward, reverse voltages Maximum program blocks: 8, with automatic execution Maximum run time: 999 hr per block Fuses: 3 A Slow-Blow; two each for AC line input Electrophoresis Cell Dimensions (W x D x H): 44.2 x 50.3 x 11.4 cm, horizontal format Construction: Cover: vacuum-formed polycarbonate, base: injection-molded polycarbonate Lid: Safety interlocked Weight: 10.2 kg (22.5 lb) Electrodes: 24, platinum (0.02" diameter) Temperature monitoring: Via precision temperature probe mounted in base of cell
Related Products
Bio-Rad, 0.1 to 65,000 sec In Elkin, NC, USA (CAT#: STEM-EPO-0009-YJL) BioRad Bio-Rad Vapor Trap, 1.5 liters 30 Day warranty! In Tucker, GA, USA (CAT#: STEM-EPO-0013-YJL) Bio-Rad Electrophoresis Cell Laboratory In Elkin, NC, USA (CAT#: STEM-EPO-0015-YJL) Bio-Rad 1703649 Electrophoresis Cell Laboratory In Elkin, NC, USA (CAT#: STEM-EPO-0016-YJL) Bio-Rad Cooling Module (Non-CFC) In Elkin, NC, USA (CAT#: STEM-EPO-0017-YJL) Bio-Rad CHEF-DR ll Drive Module, 43 x 26 x 14 cm In Elkin, NC, USA (CAT#: STEM-EPO-0018-YJL)