Fluke Calibration 5790B In Rochester, NY, USA, model 5790B is manufactured by Fluke power calibration instruments.
The 5790B AC Measurement Standard is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you would expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C). The 5790B is designed to meet the complete ac voltage, ac current and wideband verification requirements of the Fluke Calibration 5735A, 5720A, and 5700A Multifunction Calibrators; 5522A, 5502A, 5520A, and 5500A Multi-Product Calibrators; plus other calibrators, amplifiers like the 52120, 5725A and 5205A/5215A, and transfer standards and ac voltmeters.
The 5790B covers an alternating voltage range of 600 µV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend frequency range to 30 or 50 MHz.
The 5790B in combination with the Fluke A40B Current Shunts now allow you to make direct, absolute or relative current measurements without the need to perform any calculations.
The 5790B may be used alone as a measurement device or as a transfer standard when compared to an external dc source. In either case the normally tedious switching and calculations are performed automatically by the 5790B, and the resulting ac/dc difference is displayed directly on the easy-to-read 6.5-inch full-color capacitive touch screen display.

Specification

Condition: Used
Dimensions:
Height: 17.8 cm (7 in) standard rackmount + 1.5 cm (0.6 in)
Width: 43.2 cm (17 in)
Depth: 62 cm (24.8 in)
Maximum power requirements: 5790B: 100 VA
Weight: 5790B: 24 kg (53 lb)
With wideband: 24.5 kg (54 lb)
Line power: 50 Hz or 60 Hz; 100 V - 120 V, 220 V - 240 V
100V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V
Safety: Complies with UL1244 and IEC 348-1976 and IEC 1010 and CSA C22.2 No. 231 and ANSI/ISA S82
Remote interfaces: RS-232, IEEE-488
Confidence level: 99% unless otherwise specified

Related Products

Fluke Calibration 4181 In Rochester, NY, USA (CAT#: STEM-AIPO-0411-YJL)
Fluke Calibration 9142 In Rochester, NY, USA (CAT#: STEM-AIPO-0412-YJL)
Fluke 1949 In New Smyrna Beach, FL, USA (CAT#: STEM-AIPO-0415-YJL)
Fluke 1948 In New Smyrna Beach, FL, USA (CAT#: STEM-AIPO-0416-YJL)
Fluke 1941 In New Smyrna Beach, FL, USA (CAT#: STEM-AIPO-0417-YJL)
Fluke 1942 In New Smyrna Beach, FL, USA (CAT#: STEM-AIPO-0418-YJL)

Other recommended products

Advertisement