Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Automatic Decap Centrifuge (Frozen Type) CTK132R, 4000r/min, Hunan Xiang Yi Laboratory Instrument Development Co., Ltd. (CAT#: STEM-LC-0254-YJL)

Highlights

Vacuum blood collection tubes are automatically uncapped, with a success rate of >90%
Suitable for two lengths of 100mm and 75mm
Touch panel, large-screen LCD display, easy to operate

Cat Number: STEM-LC-0254-YJL

Application: For blood centrifugation.

Model: CTK132R(Frozen Type)

Add to Cart



Description

Automatic Decap Centrifuge (Frozen Type) CTK132R, 4000r/min, model CTK132R(Frozen Type) is manufactured by Hunan Xiang Yi Laboratory Instrument Development Co., Ltd. When collecting blood samples, vacuum blood collection tubes are commonly used, and the tube cap must be removed manually after blood centrifugation is completed, which is inefficient. The vibration generated when the cap is removed may cause the blood to remix and increase the risk of bacterial infection. CTK132R automatic decapping centrifuges have obvious effects, which solve the problem of decapping vacuum blood collection tubes, and are ideal testing instruments.

Specification

Max speed: 4000r/min
Max RCF: 3370×g
Maximum separation number: 128 (4×32) vacuum blood collection tubes
Time control: 1S~99min59S (LCD)
Temperature setting range: 0~35℃
Temperature control accuracy: ±1℃
Compressor unit: Imported high-performance Compressor unit, environmentally friendly refrigerant (R404a)
Power consumption: 2000W
Power supply: AC220V 50Hz 15A
Noise: ≤65dB(A)
Dimension: 565×670×850mm(L×W×H)
Net weight: 148kg

Features

Vacuum blood collection tubes are automatically uncapped, with a success rate of >90%
Suitable for two lengths of 100mm and 75mm
Touch panel, large-screen LCD display, easy to operate
Adopt AC variable frequency motor, high speed control precision, with fast speed up and down functions
Automatic calculation of RCF value
Adopt special shock absorber, good vibration reduction effect, with automatic balance function
Electronic door lock is adopted, which has strong safety performance. If the door cover is not closed properly, the centrifuge cannot start; if the door cover is opened abnormally during operation, it will automatically stop.

Related Products

Automatic Decap Centrifuge CTK132C, 4000r/min (CAT#: STEM-LC-0255-YJL)
Automatic Decap Centrifuge (Frozen Type)CTK120R, 4000r/min (CAT#: STEM-LC-0256-YJL)
Biosafety Room Temperature Centrifuge CL4S, 4000r/min (CAT#: STEM-LC-0257-YJL)
Microcomputer Control Large Capacity Refrigerated Centrifuge DL-6MC,Angle Rotor: 6000r/min; Horizontal Rotor: 4200r/min (CAT#: STEM-LC-0258-YJL)
CL5S Biosafety Refrigerated Centrifuge, 4000r/min (CAT#: STEM-LC-0259-YJL)
Advertisement