Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

WRS-1B Digital Melting Point Apparatus, 220V±22V, 50Hz±1Hz, 80w, Shanghai INESA Physico-Optical Instrument CompanyLimited (CAT#: STEM-DTE-3011-LGZ)

Highlights

1. The temperature system uses platinum resistance with high linearity as the detection element, and adopts PID adjustment technology to improve the accuracy and reliability of the melting point.
2. By establishing a communication interface, the working parameters can be printed or saved, and the instrument uses the capillary specified in the Pharmacopoeia as the sample tube.

Cat Number: STEM-DTE-3011-LGZ

Application: It can be widely used in chemical industry and pharmaceutical research, and is an essential instrument for the production of drugs, spices, dyes and other organic crystal substances.

Model: WRS-1B

Add to Cart



Description

Adopt photoelectric automatic detection, color LCD screen display, numeric keyboard input for different models. The instrument can be installed with one or three capillaries for measurement, and the average melting point is automatically obtained. It has automatic display of initial melting and final melting, and automatic recording of melting curve.

Specification

Measuring range: room temperature~320°C
Measurement method: Automatic
Minimum indication: 0.1°C
Heating rate: 0.2°C/min, 0.5°C/min, 1°C/min, 1.5°C/min, 2°C/min, 3°C/min, 4°C/min, 5°C/min
Indication error: ≤200°C: ±0.4°C;>200°C : ±0.7°C
Indication repeatability: 0.3°C when the heating rate is 1.0°C/min
Linear heating error: ±10%
Processing capacity: 1 stick
Capillary size: outer diameter φ1.4mm, inner diameter φ1.0mm, length 90mm
Sample height: 3mm
Display mode: 5.6 inch color LCD screen
Calibration method: multi-point calibration
Communication interface: RS232/USB
Printer model: thermal printer RD-TH32 SC (optional)
Power supply: 220V±22V, 50Hz±1Hz, 80w
Instrument size: 360mm×290mm×170mm
Instrument net weight: 9kg

Features

1. The temperature system uses platinum resistance with high linearity as the detection element, and adopts PID adjustment technology to improve the accuracy and reliability of the melting point.
2. By establishing a communication interface, the working parameters can be printed or saved, and the instrument uses the capillary specified in the Pharmacopoeia as the sample tube.

Related Products

SGW®-682 Automatic Video Melting Point Apparatus, 100~240VAC, 50/60Hz, 150w, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3002-LGZ)
SGW®-635 Automatic Image Grease Melting Point (Slip Point) Tester, 220V±22V, 100W, 50Hz, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3003-LGZ)
SGW®-650 Automatic Image Melting Point Apparatus, 220V±22V, 50Hz±1 Hz, 100w, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3004-LGZ)
SGW®-630 Automatic Image Melting Point Apparatus, 220V±22V, 50Hz±1 Hz, 100w, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3005-LGZ)
WRS-3A Melting Point Apparatus (Visual, Automatic), 220V±22V, 50Hz±1Hz, 180w, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3006-LGZ)
WRS-2C Melting Point Apparatus, 220V±22V, 50 Hz±1Hz, 120w, Shanghai INESA Physico-Optical Instrument Company Limited(CAT#-STEM-DTE-3007-LGZ)
Advertisement