Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

996 PDA Photo Diode Array Detector, Waters (CAT#: STEM-CPO-0751-ZJF)

Highlights

Increase Confidence: Automatically identify peaks using the Library Match function. Assess peak homogeneity and identity using Waters unique Spectral Contrast and library match algorithms.
See the Finest Spectral Details: The true 1.2 nm optical resolution and optics bench efficiency enables the combination of narrow slit width with high digital resolution into the markets only true no-compromise optical system.
Easy to Set-up and Run: Due to the "no-compromise" optics design, no choices need to be made regarding chromatographic or spectral sensitivity. Turn the 996 on and run.

Cat Number: STEM-CPO-0751-ZJF

Application: For chromatography

Model: 996

Add to Cart



Description

The manufacturer of the 996 PDA Photo Diode Array Detector, Waters is Waters.
Refurbished Waters 996 PDA photo diode array detector (available part numbers: WAT067002, WAT057002 & WAT058510). Optional: Waters 996 analytical cell 10mm (p/n WAT057919).
The Waters 996 Photodiode Array Detector is the most versatile HPLC Photodiode Array Detector available with the highest sensitivity. Operates exclusively with Waters Empower software to provide complete spectral acquisition and results management.

Specification

Condition: Refurbished, Certified Pre-owned
Wavelength Range: 190 to 800 nm
Wavelength Accuracy: ±1nm
Linearity Range: 5% over -0.1 to 2.0 AU
Spectral Resolution: 1.2 nm per photodiode
Baseline Noise: 5 x 10 -5 AU peak-to-peak
Drift: 1 x 10 -3 AU/hour at 254 nm (after warmup)
Operating Temperature: 4 to 40 °C (39 to 104 °F)
Operating Humidity: 20 to 80% non-condensing
Standard Pathlength: 10 mm
Semi-Preparative Pathlength: 3 mm
Microbore Pathlength: 6 mm
Inert Pathlength: 10 mm

Features

Increase Confidence: Automatically identify peaks using the Library Match function. Assess peak homogeneity and identity using Waters unique Spectral Contrast and library match algorithms.
See the Finest Spectral Details: The true 1.2 nm optical resolution and optics bench efficiency enables the combination of narrow slit width with high digital resolution into the markets only true no-compromise optical system.
Easy to Set-up and Run: Due to the "no-compromise" optics design, no choices need to be made regarding chromatographic or spectral sensitivity. Turn the 996 on and run.

Related Products

991 PDA Photo Diode Array Detector, Waters
Acquity Arc UHPLC System, Waters
Acquity Column Heater/Cooler, Waters

Other recommended products

Advertisement