A2 Type Anaerobic Incubator, Dimensions 140×73×70cm, RT+3℃ ~ 60℃ (CAT#: STEM-GLE-1111-LGH)

Highlights

1.Outstanding performance
(1) Adopt high-impedance motor cross-flow fan, horizontal air outlet arc circulation design; electric heating power balance temperature regulation + temperature self-protection heater. Ensure good temperature uniformity and small temperature fluctuation.
(2) Microcomputer fuzzy PID temperature controller, automatic gas replacement program, precise control, and meet diverse temperature control requirements.

Cat Number: STEM-GLE-1111-LGH

Application: It can provide strict anaerobic constant temperature culture conditions and a systematic and scientific working area.

Model: HYQX-A2-TSD

Add to Cart



Description

1.Outstanding performance
(1) Adopt high-impedance motor cross-flow fan, horizontal air outlet arc circulation design; electric heating power balance temperature regulation + temperature self-protection heater. Ensure good temperature uniformity and small temperature fluctuation.
(2) Microcomputer fuzzy PID temperature controller, automatic gas replacement program, precise control, and meet diverse temperature control requirements.
(3) The TSZ type adopts the international first-line brand Cubigel refrigeration compressor with excellent comprehensive performance.
2. Smart and convenient
(1) 7'' TFT 65K color touch screen, high-definition display (temperature and humidity, concentration, pressure), intuitive and easy to operate.
(2) The anaerobic environment formed by the sampling room and the operation room can be automatically executed with one key, which greatly saves labor costs and saves time.
3. Safe and reliable
(1) It has a safety monitoring function, which can set the temperature protection value, automatically disconnect the power supply of functional components when an abnormality occurs, and issue an alarm.
(2) External independent temperature protector, one more safety guarantee, can avoid the occurrence of experimental accidents.
4. The craftsmanship is exquisite
(1) SUS304 brushed stainless steel is made of fine workmanship, with strong wear resistance, fine and smooth, and easy to clean.
(2) The doors of the sampling room and the operation room are made of transparent bulletproof glass, which has good light transmission effect and pressure bearing performance.
(3) The sampling room has a large space, and more petri dishes or scientific instruments can be transferred at one time; it is equipped with a moving track slide plate, which makes the transfer of objects more convenient.
(4) The panel of the operating room can be detached, which is convenient for placing larger scientific instruments and cleaning up the internal space.
5. Energy saving and environmental protection
(1) With the set oxygen concentration as the control parameter, it is not necessary to supplement the mixed gas at any time, which can greatly save the gas consumption.
(2) The use of oil-free vacuum pump (no oil and gas will be generated during the use of the equipment), R-134a fluorine-free environmental protection refrigerant, does not pollute the experimental environment.
6. Data collection is simple
(1) Standard USB data recording serial port, convenient to record and store experimental data; support USB automatic upgrade of control program.
(4) Optional micro thermal printer or micro needle printer.

Specification

Culture room temperature range: TS/TSD: ambient temperature 15℃ ~ 30℃, temperature control range: RT+3℃ ~ 60℃, TSZ: ambient temperature 15℃ ~ 30℃, temperature control range: 10℃ ~ 60℃
Temperature uniformity: ≤±1℃
Temperature fluctuation: ≤±0.5℃
Anaerobic grade: Oxygen content in operation room ≤0.1%
Oxygen concentration display range: 0 ~ 21%
Carbon dioxide concentration display range: 0 ~ 20%
Carbon dioxide concentration control range: 0 ~ 20%
Humidity display range: 0 to 100%
Time of anaerobic formation in sampling chamber: ≤15 minutes
Anaerobic method of sampling chamber formation: vacuum + gas displacement type (99.99% nitrogen or hydrogen 5% carbon dioxide 10% nitrogen 85% mixture)
Sampling chamber to form micro-aerobic mode: vacuum + gas displacement type (99.99% nitrogen or oxygen 5% carbon dioxide 10% nitrogen 85% mixture)
Operation room forming anaerobic state time: ≤1.5 hours operation room oxygen content ≤0.3%
Operation chamber formed anaerobic mode: gas displacement type (99.99% nitrogen or hydrogen 5% carbon dioxide 10% nitrogen 85% mixture) + micro flow control
The operation room forms micro-aerobic mode: gas displacement type (99.99% nitrogen or oxygen 5% carbon dioxide 10% nitrogen 85% mixture) + micro-flow control
Operation room anaerobic environment maintenance: automatic
Control mode of anaerobic formation: automatic execution with one key
Sterilization method: ultraviolet sterilization lamp ×1
Sampling chamber size W*D*H(cm): 40×33×32
Operation room size W*D*H(cm): 91×65×60
Culture chamber size W*D*H(cm): TS/TSD: 42×30×50
External dimension W*D*H(cm)
TS/TSZ: 140×73×137, TSD: 140×73×70
Packing size W*D*H(cm): 154×87×155
Display interface: 7 "color touch screen P.I.D. controller, Chinese and English display
Power supply: 1Ø 220V 50Hz
Gas supply requirements: gas purity 99.99%, 0.05mpa, continuous gas supply
Ambient temperature: Available ambient temperature: 5 ℃ to 35 ℃ Optimal ambient temperature: 15 ℃ to 30 ℃
Type III: standard pressure sensor, oxygen sensor, temperature sensor, the value of the same screen display; Type A: standard with pressure sensor, oxygen sensor, carbon dioxide sensor, temperature sensor, humidity sensor, numerical display with the same screen, standard with USB data recording serial port; Support control program USB automatic upgrade; Type A2: standard pressure sensor, oxygen sensor, carbon dioxide sensor, temperature sensor, humidity sensor, the value of the same screen display; Independent carbon dioxide concentration control, standard USB data recording serial port; Support control program USB automatic upgrade, standard wireless, wired remote alarm module, remote monitoring through mobile APP
Note: TS: Culture room without refrigeration system; TSZ: No culture room, operation room overall temperature control, refrigeration system; TSD: table top (no bracket), culture room, no refrigeration system

Features

1.Outstanding performance
(1) Adopt high-impedance motor cross-flow fan, horizontal air outlet arc circulation design; electric heating power balance temperature regulation + temperature self-protection heater. Ensure good temperature uniformity and small temperature fluctuation.
(2) Microcomputer fuzzy PID temperature controller, automatic gas replacement program, precise control, and meet diverse temperature control requirements.
(3) The TSZ type adopts the international first-line brand Cubigel refrigeration compressor with excellent comprehensive performance.
2. Smart and convenient
(1) 7'' TFT 65K color touch screen, high-definition display (temperature and humidity, concentration, pressure), intuitive and easy to operate.
(2) The anaerobic environment formed by the sampling room and the operation room can be automatically executed with one key, which greatly saves labor costs and saves time.
3. Safe and reliable
(1) It has a safety monitoring function, which can set the temperature protection value, automatically disconnect the power supply of functional components when an abnormality occurs, and issue an alarm.
(2) External independent temperature protector, one more safety guarantee, can avoid the occurrence of experimental accidents.
4. The craftsmanship is exquisite
(1) SUS304 brushed stainless steel is made of fine workmanship, with strong wear resistance, fine and smooth, and easy to clean.
(2) The doors of the sampling room and the operation room are made of transparent bulletproof glass, which has good light transmission effect and pressure bearing performance.
(3) The sampling room has a large space, and more petri dishes or scientific instruments can be transferred at one time; it is equipped with a moving track slide plate, which makes the transfer of objects more convenient.
(4) The panel of the operating room can be detached, which is convenient for placing larger scientific instruments and cleaning up the internal space.
5. Energy saving and environmental protection
(1) With the set oxygen concentration as the control parameter, it is not necessary to supplement the mixed gas at any time, which can greatly save the gas consumption.
(2) The use of oil-free vacuum pump (no oil and gas will be generated during the use of the equipment), R-134a fluorine-free environmental protection refrigerant, does not pollute the experimental environment.
6. Data collection is simple
(1) Standard USB data recording serial port, convenient to record and store experimental data; support USB automatic upgrade of control program.
(4) Optional micro thermal printer or micro needle printer.
Advertisement