Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Abbott Cell-Dyn Ruby Hematology System, 230 μ, Abbott (CAT#: STEM-CTEPO-0041-YJL)

Highlights

Uses MAPSS technology to enumerate and differentiate White Blood Cells and provide the performance needed for patient samples
Uses optical laser light scatter analysis to provide both Red Blood Cell and Platelet counts
Can process up to 84 CBCs and Differentials per hour

Cat Number: STEM-CTEPO-0041-YJL

Application: For in vitro diagnostic use only.

Model: Cell-Dyn Ruby

Add to Cart



Description

Abbott Cell-Dyn Ruby Hematology System, 230 μ, model Cell-Dyn Ruby, is manufactured by Abbott.

Specification

Condition: Certified Pre-Owned
Maximum Throughput (Autoloader Mode): CBC + Differential: Up to 84 per hour
Sample Volume: Open Mode 150 μL, Sample Loader 230 μL
Reagents: Only 4 reagents including reticulocytes
Technology
WBC and differential: 4 angle optical MAPSS Multiple Scatterplot Analysis
Platelets: Dual angle optical analysis, no extra reagent, no reflex testing requirement
Reticulocytes: New Methylene Blue NCCLS method, supravital staining technique
Analytical Measurement Ranges
WBC: 0.02–246.8 x 103/μL
RBC: 0.00–7.50 x 106/μL
HGB: 0.0–25.0 g/dL
HCT: 8.3-79.8%
MCV: 58–139 fL
RDW: 10.0-29.8%
PLT: 0.0–3000 x 103/μL
MPV: 4.3-17.2 fL
RETC: 0.2–22.9%
Data Management: Windows®-based operating system. Rules-based result annotations. Full on-board QC package. Levey-Jennings plots. Moving Averages. Westgard rules. 10,000 results stored with graphics. Auto calibration online guide.
System Control Center: A single computer with color touch-screen monitor, keyboard, and mouse
Dimensions (HxWxD):
Height: 19.25 inches (49.9 cm)
Width: 34 inches (86.4 cm)
Depth: 30.25 inches (76.8 cm)
Weight: 232 pounds (105.2 kilograms)
Electrical Requirements*: VAC 100-240V, 50/60Hz
Maximum Power Consumption*: 550 watts

Features

Uses MAPSS technology to enumerate and differentiate White Blood Cells and provide the performance needed for patient samples
Uses optical laser light scatter analysis to provide both Red Blood Cell and Platelet counts
Can process up to 84 CBCs and Differentials per hour
MultiAngle Polarized Scatter Separation (MAPSS) laser technology provides enhanced first-pass efficiency, with accurate WBC enumeration and identification using 4 angles of light scatter on up to 10,000 cells per dilution
Uses only 4 reagents including reticulocytes
Sampling: Open and Closed
Reagents: 3 and Retic
Load up Capacity: 50 tubes with 10 per rack
Maintenance Requirements: Auto-clean (15 min) daily and manual cleaning of syringes, shear valve, dil/sheath filter weekly

Related Products

Sysmex SP100i Diagnostic Analyzer, 60 tests/hour, Sysmex Corporation (CAT#: STEM-CTEPO-0089-YJL)
Sysmex XE-5000 Automated Hematology System, Sysmex Corporation (CAT#: STEM-CTEPO-0090-YJL)
Sysmex XE2100 Hematology Analyzer, 150 tests/hour, Sysmex Corporation (CAT#: STEM-CTEPO-0091-YJL)
Sysmex XP-300 Automated Hematology Analyzer, 60 samples/hour, Sysmex Corporation (CAT#: STEM-CTEPO-0092-YJL)
Sysmex XT 2000i Automated Hematology Analyzer, Main Unit: 20.x x 24.8 x 19.7 / 114.6, Sysmex Corporation (CAT#: STEM-CTEPO-0093-YJL)
Advertisement