Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1200 Series - G1367C HPLC Well Plate Autosampler, Agilent Technologies (CAT#: STEM-C-0075-LGZ)

Highlights

1. The increased pressure range enables the Agilent 1200 Fast Resolution System to use today's chromatography technology (sub-2 micron columns).
2. High-speed, carry-over design with minimal flow through.
3. Increase injection speed and increase sample throughput.

Cat Number: STEM-C-0075-LGZ

Application: For HPLC system.

Model: 1200 Series - G1367C

Add to Cart



Description

The manufacturer of Agilent 1200 Series - G1367C HPLC Well Plate Autosampler is Agilent Technologies. Model is 1200 Series - G1367C. The Agilent 1200 Series Autosampler is designed to be used with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. Autosampler controlled by Agilent 1200 Series Control Module or Agilent ChemStation.

Specification

Condition: used
Weight: 15.5 kg (34.2 lbs)
Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
Line frequency: 50 or 60 Hz, ±5 %
Power consumption (apparent power): 300 VA Maximum
Power consumption (active power): 200 W Maximum
Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
Operating Altitude: Up to 2000 m (6500 ft)
Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler

Features

1. The increased pressure range enables the Agilent 1200 Fast Resolution System to use today's chromatography technology (sub-2 micron columns).
2. High-speed, carry-over design with minimal flow through.
3. Increase injection speed and increase sample throughput.
4. The overlapping injection method is adopted to increase the production capacity.
5. Minimal delay volume for fast gradients and fast equilibration when bypassing the autosampler after sample injection.
6. Flexible and convenient sample handling for different types of sample containers such as vials and well plates. Using a 384-well plate allows you to process up to 768 samples unattended.
7. Peltier temperature control for thermally unstable samples at 4 – 40 °C (possible upgrade from non-isothermal to isothermal versions).

Related Products

Agilent 1100 Series - G1313A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0034-LGZ)
Agilent 1100 Series - G1329A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0043-LGZ)
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler, Agilent Technologies(CAT#-STEM-C-0052-LGZ)
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler, Agilent Technologies(CAT#-STEM-C-0054-LGZ)
Agilent 1100 Series - G1389A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0056-LGZ)
Agilent 1100 Series - G2260A HPLC Preparative Autosampler, Agilent Technologies(CAT#-STEM-C-0058-LGZ)
Advertisement