Agilent 8453 HPLC UV/VIS Detector, Agilent (CAT#: STEM-C-1409-LGZ)

Highlights

1. The wavelength range is 190-1100 nm.
2. Easy to use-directly access the battery bracket and battery, and the built-in button trigger the measurement in front.
3. Stable optical-due to the highlight accuracy of the ceramic spectrometer and low-noise electronic devices authorized by Caliss Zeiss, it has excellent wavelength reproduction.

Cat Number: STEM-C-1409-LGZ

Application: For HPLC system.

Model: 8453

Add to Cart



Description

The manufacturer of Agilent 8453 HPLC UV/VIS Detector is Agilent. Model is 8453. The HP/Agilent 8453 UV/Vis Spectrophotometer is the heart of a powerful UV/Vis system. Spectrophotometers offer all the benefits of diode arrays - fast scanning, excellent sensitivity, almost absolute wavelength reproducibility, exceptional durability and reliability, minimal maintenance and open sample area, and excellent optical performance. The standard wavelength range is 190 ~ 1100 nm, the resolution is greater than 2 nm, and the stray light is less than 0.03%.

Specification

Condition: used
Wavelength range: 190–1100 nm
Slit width: 1 nm
EP resolution test: > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm
Stray light:
< 0.03 % at 340 nm (NaNO2, ASTM)
< 0.05 % at 220 nm (NaI, ASTM)
< 1 % at 198 nm (KCl, EP)
Wavelength accuracy:
< ± 0.5 nm 0.5-second scan (NIST 2034)
< ± 0.2 nm at 486.0 and 656.1 nm
Wavelength reproducibility: < ± 0.02 nm ten consecutive scans (NIST 2034)
Photometric accuracy:
< ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)
< ± 0.01 A at 235, 257, 313, 350, 430 nm, (potassium dichromate, EP method)
Photometric noise: < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms
Photometric stability: < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp.
Baseline flatness: < 0.001 A 0.5-second blank, 0.5-second scan, rms
Typical scan time: 5 second full range
Shortest scan time: 1 second full range
Time until next scan: 1 second full range, 0.1-second scan, up to 150 consecutive scans
System Includes:
Agilent G1103A UV-Vis Spectrophotometer
G1115AA/BA Spectral B.04.xx 32 Bit Chemstation Software or C.01.xx OpenLab Software (your choice)
Computer With Windows 7 Pro or Windows XP Operating System
Cables and Accessories

Features

1. The wavelength range is 190-1100 nm.
2. Easy to use-directly access the battery bracket and battery, and the built-in button trigger the measurement in front.
3. Stable optical-due to the highlight accuracy of the ceramic spectrometer and low-noise electronic devices authorized by Caliss Zeiss, it has excellent wavelength reproduction.
4. Flexible attachment. Agen's multi -cell transmission, PELTIER constant temperature battery bracket, SIPPER system, or automatic sampler associated with the attachment interface. Gilson automatic sampler, Labsphere Man -reflecting attachment, or custom sensor and technology optical fiber coupling.
5. GLP built-in-the serial number and firmware version number saved in the firmware. The lamp strength, wavelength accuracy and noise of the wide self -inspection procedure to ensure consistent performance. The built -in log book contains the results of self -inspection, the precautions of the instrument maintenance and the timer.
6. Easy to exchange pre -predetermined and tungsten wire lighting sources.
7. Support firmware upgrade through the built -in communication interface.

Related Products

Agilent 1200 Series - G1362A HPLC Refractive Index Detector, Agilent Technologies(CAT#-STEM-C-0073-LGZ)
Agilent 1260 Series - G1312B HPLC Binary Pump, Agilent Technologies(CAT#-STEM-C-0086-LGZ)
Agilent 1260 Series - G1315D HPLC Diode Array Detector, Agilent Technologies(CAT#-STEM-C-0087-LGZ)
Waters 2487 HPLC UV/VIS Detector, Waters Corporation(CAT#-STEM-C-0099-LGZ)
Alltech 3300 ELSD ELSD Controller, Grace(CAT#-STEM-C-0103-LGZ)
Waters 480 HPLC UV Detector, Waters Corporation(CAT#-STEM-C-0106-LGZ)