Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

GRUNT Automatic Pipette Workstation, Shanghai Bojian Bio (CAT#: AM-AUTO-0304-LY)

Highlights

Automate 12 preparations and change liquids in 1 day, complete within 6-24 hours, and only take 20 minutes for manual care.
The working mode is flexible, and only one of the liquid mixing or liquid changing can be done, or the two can be completed in order.
Unique liquid exchange method, after a round of pressure change, determine the volume change of the solution, determine the amount of new preparation added, cycle this process until the liquid exchange rate reaches 99%, and accurately calculate the reagent exchange rate.

Cat Number: AM-AUTO-0304-LY

Application: Large-molecule biopharmaceuticals such as proteins, antibodies, vaccines, etc. are automated, high-throughput preparations for formulation, exchange and concentration, and accelerated protein formulation screening.

Model: GRUNT

Add to Cart



Description

The GRUNT Automatic Pipette Workstation is manufactured by Shanghai Bojian Bio. The workstation can automatically complete 12 kinds of preparation and liquid replacement in one day, in 6-24 hours, and only need 20 minutes of artificial care. There are many ways to change liquid. You can customize process parameters such as pressure, volume per cycle, number of cycles, and efficiency of changing fluids.

Specification

Pipetting range: 0.5-8 mL
Temperature: 2 °C to 40 °C

Features

Automate 12 preparations and change liquids in 1 day, complete within 6-24 hours, and only take 20 minutes for manual care.
The working mode is flexible, and only one of the liquid mixing or liquid changing can be done, or the two can be completed in order.
Unique liquid exchange method, after a round of pressure change, determine the volume change of the solution, determine the amount of new preparation added, cycle this process until the liquid exchange rate reaches 99%, and accurately calculate the reagent exchange rate.
At the same time as the pressure above the liquid level of the preparation, the filter bowl will slightly oscillate, preventing the protein from blocking the filter membrane and affecting the ultrafiltration efficiency.
Compared with centrifugal ultrafiltration, the pressure change process is gentle, has minimal effect on protein, and has high recovery rate.
A variety of liquid changing modes are available for selection. You can customize the process parameters such as pressure, volume per cycle, number of cycles, and efficiency of changing fluids.