AP Maldi Ion Source, MassTech (CAT#: STEM-MSPO-0144-ZJF)

Highlights

Fast analyses : AP/MALDI operates at atmospheric pressure; no pump down time is needed. Sample plates can be loaded in seconds.
High sensitivity : Low-femtomole to attomole sample amounts spotted on the sample plate can be detected.
Searchable MS/MS spectra : AP/MALDI generates MS and MS/MS data quickly and easily. Allows database searching for protein identification. AP/MALDI MS/MS data is much easier to acquire than MALDI-TOFs post-source decay data.

Cat Number: STEM-MSPO-0144-ZJF

Application: For measuring the mass-to-charge ratio (m/z) of one or more molecules present in a sample

Model: AP Maldi

Add to Cart



Description

The manufacturer of the AP Maldi Ion Source, MassTech is MassTech.
MassTech AP Maldi Ion Source. The original AP/MALDI ion source allows MALDI-MSn capabilities with your Thermo Finnigan LCQ Classic series ITMS.

Specification

Condition: Refurbished, Certified Pre-owned

Features

Fast analyses : AP/MALDI operates at atmospheric pressure; no pump down time is needed. Sample plates can be loaded in seconds.
High sensitivity : Low-femtomole to attomole sample amounts spotted on the sample plate can be detected.
Searchable MS/MS spectra : AP/MALDI generates MS and MS/MS data quickly and easily. Allows database searching for protein identification. AP/MALDI MS/MS data is much easier to acquire than MALDI-TOFs post-source decay data.
Complementary data : The MALDI capability, on a typically ESI instrument, allows analysis of singly charged ions and when combined with an ion trap allows MSn. Generation of MALDI data complements multiply-charged data from ESI.
Rapidly interchangeable : The design of the AP/MALDI source is similar to that of the ESI source so changing sources is simple. Switching to AP/MALDI only takes minutes.
Excellent reliability : With new pulsed dynamic focusing (PDF) technology which has been added to AP/MALDI systems, laser misalignments are eliminated and a robust stable operation is achieved. All AP/MALDI systems are delivered pre-configured/aligned, and go through rigorous quality testing.
Great Value : AP/MALDI is also the most cost effective method of getting MS/MS data from MALDI ions. Adding AP/MALDI to an existing instrument is far less expensive than purchasing a new Q-TOF or TOF-TOF instrument. And AP/MALDI provides searchable MS and MS/MS spectra that answer many of the same questions.