Beckman 508 Autosampler, 30-999 microliters In New Jersey, USA, model 508, is manufactured by Beckman - Coulter chromatography. The Beckman Coulter SystemGold Autosampler 507 provide automated handling and injection of samples into an HPLC system. Designed for easy plumping access to the injection valve and column, the units have four tray quadrants, which allow for samples to be loaded while other samples are running. The column is insulated from lab temperature fluctuations, ensuring reproducible results. In addition, if the system is not 'suitable,' autosamplers can shut down or take corrective action. Up to 96 sample vials can be loaded into four separate tray quadrants. Injection volume is programmable and includes a sample conservation mode when injecting micro sample voumes. The 507 Autosampler is also flexible in sample handling, being capable of executing up to 99 consecutive runs, i.e. series, during which different programmable methods, i.e. inject volume, analysis, etc., can be called for each series, thus allowing for individual handling of each sample vial.
Specification
Condition: Used Height: 940 mm (37 in) to chamber door, 1270 mm (50 in) to top of control panel, 1600 mm (63 in) with door open Width: 711 mm (28 in) Depth: 838 mm (33 in) Weight (uncrated): 298 kg (656 lbs.) Rotor identity: Used to limit speed to rotor maximum and provide automatic temperature control Speed range: 100 to 21,000 rpm Speed control: Actual rotor speed will be within 20 rpm of the set speed Speed display: Digital readout indicates actual rotor speed in revolutions per minute in 10-rpm increments and four significant figures Time range: 0 to 99 hours 59.9 minutes for timed runs; entries greater than 99 h 59.9 min signal "hold” or continuous operation Time display: Digital readout indicates time remaining for timed runs, time elapsed for continuous operation Temperature range: -20˚ to +40˚C Temperature control: ±2˚ for temperatures of 0˚ to ambient. Temperature control at higher or lower temperatures depends on the rotor and speed used Temperature display: Digital readouts indicates rotor temperature in degrees Celsius in 1-degree increments Acceleration: Select from 9 acceleration rates, or maximum acceleration Deceleration: Select from 9 deceleration rates, maximum dynamic braking, or a coasting stop from full speed Operating modes: Key switch selects NORMAL, ZONAL, or PROGRAM LOCK operating modes Electrical requirements: 60-Hz; 208/240 Vac nominal power | 50-Hz; 220 Vac nominal power
Features
Built-In Column Compartment for Insulation Selective Vial Access Easy Setup and Operation Programmable Injection Volume Up to 96 Sample Vials Four Separate Tray Quadrants to Load Samples While Running
Related Products
Beckman HPLC 507E In New Jersey, USA (CAT#: STEM-CPO-0067-YJL)