Easily handle increasing time and productivity pressures. The AU680 clinical chemistry analyzer provides flexibility for mid to high volume laboratories in an efficient and economical way. Operate the AU680 as a standalone system or connect it to laboratory automation and it solutions. Capable of performing 800 photometric tests per hour (up to 1200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer provides laboratories around the world with field-proven reliability and efficiency.

The AU680's intuitive graphical interface includes:
Tracking of samples
Patient Statistics
User-customized menu
Colored alerts to highlight system health
au-certified reliability enables greater uptime, quick and easy parts replacement
No tools required
No more than three steps, no more than 60 seconds, for parts such as sample and reagent probes, mixers and syringes
Online help videos guide operators to use the correct techniques when performing maintenance procedures and parts replacement, increasing system uptime

In addition, the AU680 Chemistry Analyzer offers:
Trace sampling directly to the power processor via the AU680 and connect to the UniCel DxI 600/800 system for pre-analytical automation and integration of immunoassays
Command Central integrates with REMISOL Advance* for remote monitoring and access to instruments and automation consoles from a single workstation, optimizing laboratory management and improving decision-making
Cooled STAT compartment provides one-button STAT interrupt and advanced automatic QC and calibration functions
High-precision micro-sampling provides precise results
Priority sampling repetition/reflection reduces turnaround time in critically ill patients
Durable ISEs minimize downtime and reduce operating costs
Large 150-sample rack loader provides optimal sample handling during peak workloads
Whole blood sampling capability for HbA1c testing

Specification

Condition: certified pre-owned
Analytical System: Fully automated, random-access clinical chemistry system with STAT capability
Analytical Principles: Spectrophotometry and potentiometry
Analytical Types: Endpoint, rate, fixed point and indirect ISE
Analytical Methods: Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE
Simultaneously Processed Analytes: 60 photometric tests + 3 ISE
Throughput: 800 photometric tests/hour; up to 1,200 with ISE
Sample Types: Serum, plasma, urine, whole blood (HbA1c) and other fluids
Sample Feeder: Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading
Sample Tubes: In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
STAT Samples: Up to 22 positions for STAT samples, barcoded primary tubes
Sample Volume: 1–25 μL in 0.1 μL increments (1–25 μL for repeats)
Reagent Supply: 60 positions for R1, 48 positions for R2; refrigerated: 4–12°C; handling of 3-shot reagents
Reagent Volume: R1: 15–250 μL; R2: 15–250 μL; in 1 μL increments
Total Reaction Volume: 120–425 μL
Reaction Cuvette: Quartz cuvettes
Reaction Time: Up to 8 minutes, 40 seconds
Reaction Temperature: 37°C
Mixing Method: With rotating paddles after dispensing sample and reagent
Photometry System: Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible
Wavelength: 13 different wavelengths between 340–800 nm
Cuvette Cleaning: Comprehensive cleaning with detergents
Calibration: Autocalibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration)
Quality Control: Auto QC, cooled QC positions
Test Requisition: Individual and profile test requisition via online, mouse, function keys or touch screen
Safety: Clot detection and crash prevention for sample and reagent dispenser
Online: Full uni- and bi-directional communication possible
Software: Windows 7®
Data Storage: Sample number: 100,000 samples. Reaction data: 200,000 tests.
Dimensions (WxHxD): ANL 1,950×1,280×1,000
Power Supply: 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA

Related Products

Siemens ADVIA Centaur XPT Immunoassay System, Sample Size Max 200 μL, Siemens (CAT#-STEM-AIAEPO-0094-LGZ)
Siemens Dimension EXL 200 Chemistry Analyzer, Patient Sample Capacity 60, Siemens (CAT#-STEM-AIAEPO-0095-LGZ)
Siemens Dimension EXL LM Chemistry Analyzer, Patient Sample Capacity 60, Siemens (CAT#-STEM-AIAEPO-0096-LGZ)
Siemens Dimension RXL HM Chemistry Analyzer, 110V-220V, Siemens (CAT#-STEM-AIAEPO-0097-LGZ)
Siemens Dimension RXL LH RMS Chemistry Analyzer, Patient Sample Capacity 60, Siemens (CAT#-STEM-AIAEPO-0098-LGZ)
Siemens Dimension RXL MAX Chemistry Analyzer, 110V or 220V, Siemens (CAT#-STEM-AIAEPO-0099-LGZ)
Advertisement