Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Beckman Coulter LS6500 Liquid Scintillation Counter, Beckman Coulter (CAT#: STEM-CTEPO-0120-YJL)

Highlights

32,768-Channel Multichannel Analyzer
Advanced Photomultiplier Design
Interlocking Lead Shielding

Cat Number: STEM-CTEPO-0120-YJL

Application: For counting

Model: LS6500

Add to Cart



Description

Beckman Coulter LS6500 Liquid Scintillation Counter, model LS6500, is manufactured by Beckman Coulter. The Beckman LS-6500 systems is equipped with a 32,678 channel analyzer that delivers an effective resolution of 0.06 keV for accurate results across a variety of samples. A patented H-Number Plus external quench monitor (H-Number Plus) fitted into the system provides accurate disintegrations per minute (DPM) calculations and Automatic Quench Compensation. Both measurements are independent of sample volume or cocktail composition. The feature is also the basis for instrument calibration, color detection and correction, two-phase monitoring, unquenched window determination and multi-label DPM quench curves.
Instead of lowering the compartment to the sample chamber, the LS 6500 counter raises the sample plastic racks to the sample chamber. This design prevents possible contamination of the chamber with dust or liquid residue. As for system operations, the combination of easy-to-use menus, context-sensitive help screens and 50 user programs makes the LS 6500 a one-button system.
The System Plus and System Advantage models are equipped with powerful analysis tools. Units come with a single or dual label DPM, an exclusive H-Number Plus quench monitor as well as the Versa-Rack™ vial system which allows mixing of 20 mL and 7 mL vials. Enhancement packs and other features can be added later to address emerging laboratory needs. Instrument has capacity for 336 standard vials (20 mL), or 648 mini-vials (7 mL) or combination thereof.

Specification

Condition: Certified Pre-Owned
Resolution: 32,768 channels, 0.06 keV per channel
Reproducibility: +/- 1% Counting Efficiency
Maximum Count Rate: Total Singles: 26 x 10^6 CPM; 3H Window: 10 x 10^6 CPM; 14C Window: 13 x ^6 CPM; Above 14 C Window: 5 x ^6 CPM
Power Requirements: 120 / 240V / BTU HR with 50/60 Hz
Instrument: 3A / 1.5A / 1230
Temperature: 7.5A / 3.8A / 3060
Inrush Current: 5A at 120V, 2.5A at 240V
Power Failure Recovery: System returns to a disrupted Automatic Count with fully charged battery
Dimensions (W x H x D / Weight): Instrument: 91.4 x 67.3 x 80 cm / 210 kg; Refrigeration Acc.: 35.5 x 56 x 73.7 cm / 45.4 kg; Printer: 39 x 10 x 30.5 cm / 5 kg
Ambient Temperature Range: 15 – 35’C
Maximum Relative Humidity: 85%
Ambient Temperature Range: 15’C to 30’C
Maximum Pull Down Time: 8 Hours
Set Point 1: 12’C +3’C
Set Point 2: 15’C +3’C
Set Point 3: 18’C +3’C
Efficiency: 2H: >/= 60% in a wide window; 14C: >/= 95/5 in a wide window

Features

32,768-Channel Multichannel Analyzer
Advanced Photomultiplier Design
Interlocking Lead Shielding
User-Selectable Output Format
GMI offers a full line of counting cocktails
Includes Full Service Installation & Basic User Training

Related Products

Perkin Elmer 2450 Microbeta2, Perkin Elmer (CAT#: STEM-CTEPO-0126-YJL)
Perkin Elmer Quantulus GCT Liquid Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#: STEM-CTEPO-0127-YJL)
Perkin Elmer Tri-Carb 4810TR Liquid Scintillation Counter, 3 H / 14C, Perkin Elmer (CAT#: STEM-CTEPO-0128-YJL)
Perkin Elmer Tri-Carb 4910TR Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#: STEM-CTEPO-0129-YJL)
Perkin Elmer Tri-Carb 5110TR Liquid Scintillation Counter, 0–2,000 keV, Perkin Elmer (CAT#: STEM-CTEPO-0130-YJL)
Wallac 1450 MicroBeta TriLux Liquid Scintillation Counter & Lumi, Wallac (CAT#: STEM-CTEPO-0131-YJL)
Advertisement