Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Benchmark Scientific BactiZapper B1000 Infrared Microsterilizer, Benchmark Scientific (CAT#: STEM-GLE-1699-LGZ)

Highlights

1. BactiZapper™ Classic provides instant sterilization for platinum loops, needles, glass tube/pipette ports and various metals.
2. The asbestos-free core element uses infrared heating to generate a temperature of 815 °C (1500 °F), completely sterilizing the instrument within 5-7 seconds. A lower temperature setting (500 °C) can be used as a "backup" and the service life is extended.
3. The ceramic heating element is securely sealed in a perforated stainless steel protective chamber, protecting the user from accidental exposure to extreme temperatures in the core area.

Cat Number: STEM-GLE-1699-LGZ

Application: To provide instant sterilization of platinum inoculating loops, needles, glass tube/pipette mouths and various metal & borosilicate glass instruments, commonly used in microbiology research.

Model: B1000

Add to Cart



Description

The manufacturer of Benchmark Scientific BactiZapper B1000 Infrared Microsterilizer is Benchmark Scientific. Model is B1000. The BactiZapper™ has an asbestos-free core element that produces temperatures of 815 °C (1500 °F) using infrared heating. Completely disinfects microorganisms in 5-7 seconds. The ceramic heating element is securely sealed in a perforated stainless steel protective chamber, protecting the user from accidental exposure to extreme temperatures in the core area. It is very compact, convenient and can be used in both anaerobic and aerobic chambers.

Specification

Condition: used
Max Temperature: 815 °C / 1,500 °F
Sterilization Time: 5-7 seconds
Chamber Diameter: 0.55 in. / 14 mm
Chamber Length: 3.94 in. / 100 mm
External Dimensions (W x D x H): 4 x 6 x 6.5 in. / 10.2 x 15.2 x 16.5 cm
Electrical Data: 120 V, 60 Hz / 230 V, 50/60 Hz
Weight: 2.9 lbs. / 1.3 kg

Features

1. BactiZapper™ Classic provides instant sterilization for platinum loops, needles, glass tube/pipette ports and various metals.
2. The asbestos-free core element uses infrared heating to generate a temperature of 815 °C (1500 °F), completely sterilizing the instrument within 5-7 seconds. A lower temperature setting (500 °C) can be used as a "backup" and the service life is extended.
3. The ceramic heating element is securely sealed in a perforated stainless steel protective chamber, protecting the user from accidental exposure to extreme temperatures in the core area.

Related Products

BMT Stericell 111 Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1258-LGZ)
BMT Stericell 111 ECO Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1259-LGZ)
BMT Stericell 22 Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1260-LGZ)
BMT Stericell 22 ECO Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1261-LGZ)
BMT Stericell 222 ECO Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1262-LGZ)
BMT Stericell 404 Dry Heat Sterilizer, MMM Group(CAT#-STEM-GLE-1263-LGZ)
Advertisement